Extension Cords 
Use only three wire extension cords that have 
three-prong grounding plugs and three-pole 
receptacles that accept the tool’s plug. 
Make sure the cord is in good condition, and 
heavy enough to carry the current your band 
saw will draw. An undersized cord will cause a 
drop in line voltage, resulting in loss of power 
and overheating. Figure 25 shows the correct 
size to use depending on cord length and the 
ampere rating on your machine’s nameplate. If 
in doubt, use the next heavier gauge. The 
smaller the gauge number, the heavier the cord. 
Repair or replace a damaged or worn cord 
immediately. 
 
 
Adjustments 
 Unplug the machine from the 
power source before making any repairs or 
adjustments. Failure to comply may cause 
serious injury. 
 
Tilting the Table 
1. 
Loosen two lock knobs (Figure 26). 
 
2.  Tilt table up to 45 degrees to the right or 
up to 10 degrees to the left. The angle can 
be read on the scale mounted to the 
trunnion. 
 
3. 
Tighten two lock knobs (Figure 26). 
 
Note: Table stop must be removed to tilt table to 
the left.
 
Adjusting 90
°°°° Table Stop 
 
1. 
Disconnect machine from power source. 
 
2.  Loosen lock knobs (Figure 26) and tilt 
table left until it rests against the table 
stop. 
 
3.  Use a square placed on the table and 
against the blade (Figure 27) to see if the 
table is 90 degrees to the blade. 
 
4. 
If an adjustment is necessary, loosen lock 
knobs, tilt table to the right, and lock in 
place. 
 
Minimum Gauge Extension Cord 
Amp  
rating 
Line 
voltage 
Total length of 
cord in feet 
Cord gauge 
(AWG) 
0-6 120 
0 to 25 
18 
25 to 50 
16 
50 to 100 
16 
over 100 
14 
6-10 120 
0 to 25 
18 
25 to 50 
16 
50 to 100 
14 
over 100 
12 
10-12 120 
0 to 25 
16 
25 to 50 
16 
50 to 100 
14 
over 100 
12 
12-16 120 
0 to 25 
14 
25 to 50 
12 
over 50 
not recommended 
Figure 25 
 
 
Figure 26 
 
 
 
 
 