Conversion to 230 Volt 
If 230 volt operation is desired, the following 
instructions must be followed: 
1.  Disconnect machine from power source. 
2.  Open the switch box and connect the leads 
according to the wiring diagram inside the 
switch box. This diagram is also shown on 
page 26 of this manual.  
3.  The 115V attachment plug supplied with the 
band saw must be replaced with a UL listed 
plug suitable for 230 volt operation, similar 
to the one shown in Figure 8. Contact your 
local authorized Walter Meier service center 
or qualified electrician for proper procedures 
to install the plug. The band saw must 
comply with all local and national codes after 
the 230 volt plug is installed. 
4.  Close the switch box 
5.  The band saw with a 230 volt plug should 
only be connected to an outlet having the 
same configuration (Figure 8). No adapter is 
available or should be used with the 230 volt 
plug. 
Extension cords 
If an extension cord is necessary, make sure the 
cord rating is suitable for the amperage listed on 
the machine’s motor plate. An undersize cord 
will cause a drop in line voltage resulting in loss 
of power and overheating. 
Use the chart in Figure 9 as a general guide in 
choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord. 
 
 
Adjustments 
Squaring Vise to Blade (90° Stop) 
For accurate cutting, the vise jaws should be 
square to the blade. Inspect as follows: 
1.  Loosen the handle (A, Figure 10) and make 
sure the bow is swiveled enough that the 
stop screw (B, Figure 10) is contacting the 
fixed screw (C, Figure 10).  
2.  Place a machinist’s square on the bed 
against the blade and the fixed jaw of the 
vise, as shown in Figure 10. The square 
should lie along the entire length of the jaw 
and blade without a gap. 
 
 
 
Figure 8 
Recommended Gauges (AWG) of Extension Cords 
Amps 
Extension Cord Length *  
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 
to 
20 10 10 10 NR NR NR 
21 
to 
30  10  NR NR NR NR NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended 
Figure 9 
 
 
 
Figure 10 
3.  If the vise and blade are not square, loosen 
the hex nut on the stop screw (B, Figure 10) 
with a 10mm wrench and rotate the stop screw 
as needed until the vise and blade are square 
whenever the stop screw is contacting the 
socket head cap screw (C, Fig 10).