Aethra d2001 nx Manual Do Utilizador
ISDN TESTER AND ANALYZER D2001
NX
USER’S MANUAL
2.4.1. Setting up an X.25 access test
In order to verify the TEI enabled to X.25 service, no parameter configuration is
needed.
needed.
Concerning the test relative the LCI, the following parameters can be defined:
1
Set the test parameters.
Called address: Enter the possible X.25 number of the remote to call. It may be the
own number, if configured as bi-directional in the Central Office.
own number, if configured as bi-directional in the Central Office.
LCI start: Enter the value of the first LCI, assigned to the access to verify.
The test does not require the insertion of a specific number to call
in order to verify the valid LCI values.
in order to verify the valid LCI values.
Range: Enter the maximum number of LCI to verify, starting from the one entered
above.
above.
2.4.2. Running an X.25 access test
Connect the instrument to the tested access and continue as follows:
1
Select ‘Use this setup for testing’ in the first SETUP page.
2
Connect the instrument as displayed on the screen and
press the right cursor key.
press the right cursor key.
3
Start the test. The test results are shown on the screen.
30
CHAPTER 2 - PERFORMING AN AUTOMATIC TEST