Victory vbc-75 Guia De Especificação

Página de 2
Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.
Continuous product development may necessitate specification changes and design without notice. 
Victory  Refrigeration,  Inc.
Reach-IIn  Blast  Chiller
Dimensional tolerance ± 
1
/
4
”   Metric dimensions (MM)
REFRIGERATION DATA
Refrigerant
Compressor BTUH*
VBC-75
R-134a
1
/
2
H.P.
9211
*BTUH @ 90°F. Ambient, +14°F. Evaporator
Copyright  January 2004
Printed in U.S.A. 010451
PART OF AGA FOODSERVICE GROUP
CABLE EXIT
POWER SOURCE
CABLE EXIT
POWER SOURCE
77.50 (1970)
ELECTRICS
54.25 (1379)
20.5 (523)
32.00 (815)
26.88 (683)
25.00 (633)
8.88 (225)
72.00 (1830)
35.50 (903)
18.75 (475)
48.50 (1230)
3.00 (75)
3.00 (75)
9.00 (230)
36.00 (915)
1.25 (30)
7.50
(192)
26.00 x 18.00
  PANS
(660 x 457)
TOP VIEW
FRONT VIEW
SIDE VIEW
Crated dim. & wts.
Ht. Width Depth
Lbs
VBC-75 86 
42
42 
559
CHARACTERISTICS
VBC-75
Capacity (lbs./90 mins.)
75
Width, Overall
35 
1
/
2
Depth, Overall 
36
Depth, Door Open 90º
58 
1
/
4
Height (incl. casters)
77 
1
/
2
Clear Door Width
18 
1
/
4
Clear Door Height
48 
1
/
2
No. of Tray Slides
12 pairs
Cabinet Voltage
208/60/1
Feed Wires (with Ground)
2
Total Amperes 
15
10 Ft. Cord Installed, (No Plug)
NOTE: If cabinet is located directly against
wall and/or under low ceiling, a minimum
clearance of 2” is required.
We reserve the right to change
specifications and product design
without notice. Such revisions do not
entitle the buyer to corresponding
changes, improvements, additions or
replacements for previously purchased
equipment.