Videolarm qmrt2-50na Guia Do Utilizador

Página de 11
- 5 -
!
!
250 ft �
3 �
4 �
5 �
8 �
13 �
Ω
300 ft  �
4 �
5 �
6 �
10 �
16 �
Ω
400 ft  �
5 �
6 �
8 �
13 �
21 �
Ω
500 ft  �
6 �
8 �
10 �
16 �
26 �
Ω
600 ft  �
8 �
10 �
12 �
19 �
31 �
Ω
800 ft  �
10 �
13 �
16 �
25 �
42 �
Ω
1000 ft  �
13 �
16 �
20 �
32 �
52 �
Ω
1250 ft  �
16 �
20 �
25 �
40 �
65 �
Ω
1500 ft  �
19 �
24 �
30 �
48 �
78 �
Ω
1750 ft  �
23 �
28 �
35 �
55 �
91 �
Ω
2000 ft  �
26 �
32 �
40 �
63 �
104 �
Ω
2500 ft  �
32 �
40 �
49 �
79 �
131 �
Ω
3000 ft  �
39 �
48 �
59 �
95 �
157 �
Ω
3500 ft  �
45 �
56 �
69 �
111 �
183 �
Ω
4000 ft �
52 �
64 �
79 �
127 �
209 �
Ω
5000 ft �
65 �
80 �
99 �
158 �
261 �
Ω
6000 ft �
78 �
95 �
119 �
190 �
313 �
Ω
8000 ft �
104 �
127 �
158 �
253 �
418 �
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Unshielded Twisted-Pair Wire Gauge  (AWG)�
Cable�
Distance�
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
24�
22�
20�
19�
18�
Unshielded Twisted-Pair Wire Gauge  (AWG)�
Distance�
24�
22�
20�
19�
18�
Unshielded Twisted-Pair Wire Gauge  (mm)�
Distance�
0.5�
0.6�
0.7�
0.8�
1.0�
3 �
4 �
5 �
8 �
13 �
Ω
4 �
5 �
6 �
10 �
17 �
Ω
5 �
7 �
8 �
13 �
21 �
Ω
6 �
8 �
10 �
16 �
26 �
Ω
9 �
10 �
13 �
21 �
34 �
Ω
13 �
16 �
19 �
31 �
51 �
Ω
17 �
21 �
26 �
42 �
69 �
Ω
21 �
26 �
32 �
52 �
86 �
Ω
26 �
31 �
39 �
62 �
103 �
Ω
32 �
39 �
49 �
78 �
129 �
Ω
38 �
47 �
58 �
94 �
154 �
Ω
43 �
52 �
65 �
104 �
171 �
Ω
51 �
63 �
78 �
125 �
206 �
Ω
64 �
78 �
97 �
156 �
257 �
Ω
77 �
94 �
117 �
187 �
309 �
Ω
102 �
125 �
156 �
249 �
411 �
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Cable�
Cable�
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
75 m �
100 m �
125 m �
150 m �
200 m �
300 m �
400 m �
500 m �
600 m �
750 m �
900 m �
1000 m�
1200 m�
1500 m �
1800 m �
2400 m �
75 m �
100 m �
125 m �
150 m �
200 m �
300 m �
400 m �
500 m �
600 m �
750 m �
900 m �
1000 m�
1200 m�
1500 m �
1800 m �
2400 m �
3 �
5 �
6 �
9 �
13 �
Ω
4 �
7 �
9 �
12 �
18 �
Ω
6 �
8 �
11 �
15 �
22 �
Ω
7 �
10 �
13 �
18 �
27 �
Ω
9 �
13 �
17 �
24 �
36 �
Ω
13 �
20 �
26 �
36 �
54 �
Ω
18 �
27 �
35 �
48 �
72 �
Ω
22 �
33 �
43 �
60 �
90 �
Ω
26 �
40 �
52 �
72 �
108 �
Ω
33 �
50 �
65 �
89 �
135 �
Ω
40 �
60 �
78 �
107 �
162 �
Ω
44 �
66 �
86 �
119 �
179 �
Ω
53 �
80 �
104 �
143 �
215 �
Ω
66 �
100 �
130 �
179 �
269 �
Ω
79 �
120 �
155 �
215 �
323 �
Ω
106 �
159 �
207 �
286 �
431 �
Ω
2.  Connect the other end of the unshielded twisted pair cable to the 
     NVT receiver.  
     
CAUTION:  The unshielded twisted pair video signal is polarity
                         dependent. The positive video wire for each camera   
                         MUST be connnected to the postitive terminal on the 
                         NVT receiver, and negative MUST be connected to 
                         negative.
3.  When using unshielded twisted pair cable you DO NOT need the 
     BNC connector.  All four BNC connectors are provided inside the 
     housing for testing purposes. Be sure that there is no video con-
     nection other than the unshielded twisted pair cable.
Wiring Notes
Wire — What to 
DO
1. 
DO use point-to-point Unshielded Twisted Pair wire, gauge 24 or 
thicker, stranded or solid, Category 2, 3, 4, or 5. 
2. The video signal may co-exist in the same wire bundle as other 
video, telephone, data, control signals, or low-voltage power. It 
is also OK to run NVT video signals in or near electromagnetic 
fields (in accordance with National Electrical Code, local, or other 
local safety requirements).
3. 
DO measure the wire distance. Use only transceivers that are 
designed for that distance.
4. 
DO make sure the pair of wires carrying the video signal is sent 
as a twisted pair
 
(e.g. the blue-white/white-blue wires twisted 
together as a pair), not a “split-pair” (e.g. blue-white conductor, 
part of one pair/orange-white conductor, part of another pair).
Wire — What NOT to DO
1. 
DO NOT USE SHIELDED TWISTED PAIR WIRE. It will 
severely degrade the distance performance. Short runs may be 
used with some signal degradation (for example elevator traveler 
cables). Multi-pair wire with an overall shield is OK. 
2. 
DO NOT USE UN-TWISTED WIRE. It will reduce the NVT   
product’s inherent interference immunity.
3. 
DO NOT allow your installation to have “bridge-taps”, loading 
coils, talk-battery, or MOV type protectors. Bridge-taps are where 
a twisted pair is connected to two twisted pairs (such as an 
extension phone at home). Bridge-taps cause reflections as the 
signal propagates, resulting in “ghosts” in the video image, and 
are to be avoided. 
4. If the phone company is providing the cable runs between 
buildings, make sure it’s “dry copper” i.e. it should have none 
of the following: dial-tone, 48 volts, loading coils, bridge-taps, 
switching, or long paths to the phone company’s central office 
and back.
5. Due to near-end crosstalk, 
DO NOT send a transmit and a 
receive signal in the same wire bundle. Exceptions: Less than 
1,000 ft (300m), or Category 5 cable, up to 2,000 ft (600m) are 
OK.
6. 
DO NOT send “Up-the-Coax” Pan/Tilt/Zoom signals through 
active (amplified) NVT transceivers.
Measure your wire distance
Note: All NVT quoted distance specifications include any coax in the 
run. It is recommended that the wire distance be measured to ensure 
that the capability of the NVT product is correct. 
Wire  resistance  may  be  measured  with  an  ohm-meter  by  shorting 
the two conductors together at the far end, and measuring the loop-
resistance  out  and  back.  Compare  your  readings  with  the  charts 
below.
7. For safety, never put NVT signals in the same conduit as 
high-voltage wiring.
8. 
WARNING — to reduce a risk of fire or electrical shock, do 
not expose this product to rain or moisture.