FOR OPTIONAL PENDANT MOUNT
1.  This unit includes a 1 1/2" NPT housing for a standard 1 1/2" 
     NPT pipe.  The RH7C can be used with other brackets
     designed with 1 1/2" male pipe threads, such as the Videolarm 
     WM20G and WM20 wall mount brackets.
2.  Attach the housing coupling (Figure 3).
NOTE:  Pipe threads should be clean and rust free.   Use a 
                  sealer (such as Teflon™ tape or silicone sealer) on the 
                  threads.
Wiring Color Code for Power
1
Camera Power (24 VAC)
Red
2
Camera Power (24 VAC)
Orange
3
Accessory Power (24 VAC)
Yellow
4
Accessory Power (24 VAC)
Green
POWER
4.  Attach the wires from the wall to the connector provided, using the  
     wiring color code chart as a guide. 
5.  Once all wiring connections are made, place the wires inside the 
     wall mount bracket and close the access door.  Secure with the 
     screw removed earlier.
6.  Clean the outside of the dome. 
Figure 2
Access panel
3.  Open the access door on the bottom of the wall mount by 
     loosening the screw nearest the mounting plate (Figure 2).
Figure 3
Add thread 
sealing tape
1.  Mount the housing assembly to the mounting bracket and
     housing coupling.  A safety cable is included with the housing to
     temporarily hold it while making wiring connections.  Loop the 
     safety cable over one of the set screws on the housing coupling 
     and make the appropriate connections using the (2) screw-down 
     connectors supplied.
2.  Undo the safety cable and twist the housing onto the housing
     coupling.  Secure all (3) setscrews provided on the housing 
     coupling (Figure 4, next column).
3.  Clean the outside of the dome.