ClearCube capio one Nota De Lançamento

Página de 2
ClearCube Public Technical Document
Document Code: TB0150MH
Topic:
Component(s) Affected:
Date:
Settings for 24-bit Color Not Available in Grid Center Client
Eon e100 and Capio One I/Ports, Grid Center Client
August 30, 2005
 TB0150 rev 8/30/2005
ClearCube Technology     8834 Capital of Texas Hwy N    Austin, Texas 78759    voice 512 652 3500   www.clearcube.com
TB0150.fm — Settings for 24-bit Color Not Available in Grid Center Client
OVERVIEW / ENVIRONMENT
24-bit color is not available in the current Grid Center I/Port clients on the Eon e100 and Capio One I/Ports. 
ClearCube has issued an update for the Grid Center I/Port clients to enable 24-bit color within RDP ses-
sions.
DETAILED DESCRIPTION
24-bit color is not available in the current Grid Center I/Port clients on the Eon e100 and Capio One I/Ports. 
ClearCube has issued a set of software updates that enable 32-bit color depth on the I/Port. These updates 
should be applied to all Eon e100 and Capio One I/Ports using the Grid Center client for which 24-bit color 
support on RDP is desired. The updates can be applied as local installations, or remotely as snap-ins. ezRe-
mote Manager software is required to install this snap-in remotely. 
Note: Do not use these patches on I8010 or I8800 I/Ports. 
 
This patch is available on the ClearCube Support Website as: 
GridCenter_client_24_bit_change.zip
 
This file contains the following:
A folder titled ezRM_patch that contains the following: 
A subfolder named Linux that contains the ezRemote Manager snap-in for Linux 
A subfolder named XPe that contains the ezRemote Manager snap-in for XPe 
A folder titled Standalone_patch that contains the following: 
A subfolder named Linux that contains the patch and a 
.sh
 file that installs it 
A subfolder named XPe that contains the patch and a 
.bat
 file that installs it 
This Technical Bulletin. 
 
To install the patch using ezRemote Manager: 
For XPe, do the following: 
1.  Download and unzip the 
GridCenter_client_24_bit_change.zip
 file. 
2.  Copy the ezRM_patch folder to the ezRemote Manager server. 
3.  Start ezRemote Manager and select the I/Port(s) to be patched. 
4.  Click the Snapin Manager icon in the menu bar. 
5.  Browse to the
 \\ezRM_patch\XPe\
 folder, select the 
install.2do 
file, and click OK
The snap-in is installed and the I/Port reboots when the installation is complete.
 
Note: Before pushing the patch to an XPe I/Port, please see Technical Bulletin TB0149, ezRemote Man-
ager Patch for XPe Write Filter