General 
6.1  Introduction 
This specification describes the host interface of HxP7250xxGLA3y0. 
The interface conforms to the following working documents of Information technology with certain limitations 
described in the section 6.3 “Deviations from Standard” on page 58 
– 
Serial ATA II: Extensions to Serial ATA Revision 2.6 
 
6.2  Terminology 
Device
 
Device indicates HxP7250xxGLA3y0   
Host
 
Host indicates the system that the device is attached to.
 
 
6.3  Deviations From Standard
 
The device conforms to the referenced specifications, with deviations described below. 
Check Power Mode
 
Check Power Mode command returns FFh to Sector Count Register when the
device is in Idle mode. This command does not support 80h as the return value
.
 
COMRESET
 
COMRESET response is not the same as that of Power On Reset.    Refer to 
section 5.1, “Reset Response” for detail. 
Download
 
Download command is aborted when the device is in security locked mode. 
COMRESET response time
  During 500ms from Power On Reset, COMINIT is not returned within 10ms as a 
response to COMRESET. 
Streaming Commands
 
When the device is in standby mode, Streaming Commands can’t be completed
while waiting for the spindle to reach operating speed even if execution time
exceeds specified CCTL(Command Completion Time Limit).
 The minimum CCTL
is 50ms.CCTL is set to 50ms when the specified value is shorter than 50ms. 
Error Recover Control 
(SCT Command set)
 
When the device is in standby mode, any command where error recovery time
limit is specified can’t be completed while waiting for the spindle to reach operating
speed even if execution time exceeds specified recovery time limit.
 The minimum
time limit is 6.5 second.
 When the specified time limit is shorter than 6.5 second,
the issued command is aborted.