Location
Units represented in this manual are for indoor use only.  Be 
sure the location chosen has a floor strong enough to support 
the total weight of the cabinet and contents. A fully loaded 
model may weigh as much as 3000 pounds! Reinforce the 
floor as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air 
circulation inside and out. Don’t pack the refrigerator so full 
that air cannot circulate. Be sure that the exterior of the unit 
has access to ample air. Avoid hot corners and locations near 
stoves and ovens.
Do not install the unit near any combustible 
material or object affected by heat or moisture.
Unit is designed to maintain 36°F (2°C) to 40°F (4°C) interior 
cabinet temperature at 65% or lower ambient relative humidity
Leveling
A level cabinet looks better and will perform better because 
the drain pan will drain properly, the doors will line up with 
the frames properly, and the cabinet will not be subject to 
undue strain.
Plumbing
Self-contained models are standard with a condensate evapo-
rator. If your unit does not have a condensate evaporator, or 
the evaporator fails, the unit’s drain must have an outlet to an 
appropriate drainage area or container.
Moisture collecting from improper drainage 
can create a slippery surface on the floor and 
a hazard to employees. It is the owner’s and 
operator’s responsibility to provide a container 
or outlet for drainage.
Electrical connection
Refer to the amperage data on pages 3-4, the serial tag, your 
local code or the National Electrical Code to be sure the unit is 
connected to the proper power source. A protected circuit of 
the correct voltage and amperage must be run for connection 
of the line cord, or permanent connection to the unit.
Self-contained units have an ON/OFF switch located directly 
behind the louvered panel covering the compressor section. 
Simply turn the switch to ON to begin operation.
The power switch should be turned to OFF and 
the unit disconnected from the power source 
whenever performing service or maintenance 
functions.
D
A
R
NGE
CAUTION
Units represented in this manual are for indoor use only.  All 
self-contained units were tested at the factory to assure proper 
operation. The unit should not be installed directly next to high 
heat generating equipment (ranges, griddles, etc.). Be sure the 
location chosen has a counter strong enough to support the 
total weight of the cabinet and contents. A fully loaded model 
may weigh as much as 2000 pounds! Reinforce the counter as 
necessary to provide for maximum loading.
These units are installed by “dropping” them into the counter 
from above. The counter cutout sizes are as follows:
48” wide units — 18.62" x 23.62" (47.3 cm x 60.0 cm)
72” wide units — 18.62" x 32.62" (47.3 cm x 82.9 cm)
Self-contained F5 Series units require airflow to the 
compressor. Two louvers are provided with each unit and 
should be installed as illustrated on page 9.
Unit is designed to maintain 36°F (2°C) to 40°F (4°C) interior 
cabinet temperature at 65% or lower ambient relative humidity.
Plumbing
Self-contained models are standard with a condensate 
evaporator. If, for some reason, a unit does not have a 
condensate evaporator, or the evaporator fails, the unit’s 
drain must have an outlet to an appropriate drainage area or 
container.
Moisture collecting from improper drainage 
can create a slippery surface on the floor and 
a hazard to employees. It is the owner’s and 
operator’s responsibility to provide a container 
or outlet for drainage.
Electrical connection
Refer to the amperage data on pages 3 & 4, the serial tag, 
your local code or the National Electrical Code to be sure the 
unit is connected to the proper power source. A protected 
circuit of the correct voltage and amperage must be run for 
connection of the line cord, or permanent connection to the 
unit.
Self-contained units have an ON/OFF switch in the junction 
box. Simply turn the switch to ON to begin operation.
The power switch should be turned to OFF and 
the unit disconnected from the power source 
whenever performing service or maintenance 
functions.
CAUTION
D
A
R
NGE
D
A
R
NGE
INSTALLATION: SELF-CONTAINED F15 SERIES
INSTALLATION: SELF-CONTAINED F5 SERIES