Kent Euroclean 10 Guia Do Utilizador

Página de 12
 9 - FORM NO. 56041434 - SelectSpot
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
WARNING !
To reduce the risk electric shock or injury, unplug the power cord before servicing.
1
Toggle the Power Switch (15) to the MIDDLE position to turn both the vacuum motor and the solution pump OFF.
2
DISCONNECT THE POWER CORD (13).
3
Move the machine to a designated waste water “DISPOSAL SITE”.
4
Disconnect the Hose Assembly (6) from the machine.
5
Unstrap the Latches (2) and lift the Recovery Tank (4) from the machine.
6
Remove the Recovery Tank Lid (3), empty the tank and rinse with clean water.
7
Tip the Solution Tank (1) over to empty unused water or solution.  Rinse the tank thoroughly if any cleaning chemical was used.
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
MAINTENANCE SCHEDULE
MAINTENANCE ITEM
DAILY
WEEKLY
YEARLY
Clean the Hand Tool
X
Check the Power Cord for Damage
X
**Flush Pump System
X
Clean the Vacuum Motor Filters
X
*Check the Vacuum Motor Brushes
X
*Have Kent check the carbon motor brushes once a year or after 500 operating hours.
**If you use cleaning chemicals in the Solution Tank (1) the pump system should be flushed clean after each use.
8
Store the machine indoors in a clean, dry place.  Keep from freezing.  Leave the tanks open to air them out..
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
FLUSHING PUMP SYSTEM
1
Move the machine to a designated waste water “DISPOSAL SITE”.
2
Fill the Solution Tank (1) with clean hot water.
3
Plug the machine in and toggle the Power Switch (15) to the UP position.
4
Pull and hold the trigger on the Hand Tool (7) until all of the water has emptied from the tank.
____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
VACUUM MOTOR MAINTENANCE
Once a month, check the vacuum motor to make sure the airways are not blocked.  Clear hose of debris and keep the vacuum motor exhaust area
clean.
Have Kent check the carbon motor brushes once a year or after 500 operating hours.  Replace the carbon brushes if they are worn to 3/8” (9.5 mm)
or less.
IMPORTANT !
Motor damage from failure to service the carbon brushes is not covered under warranty.
AFTER USE