Ricoh AP400 Guia Do Utilizador

Página de 154
Remote Maintenance by telnet
105
7
Access Control
Use the access command to view and configure access control. You can also
specify two or more access ranges.
❖ Reference
msh> access
❖ Configuration
msh> access 
 range start-address end-address
✩ represents a target number between 1 and 5. (Up to five access ranges
can be registered and selected.)
Example: To specify accessible IP addresses between 192.168.0.10 and
192.168.0.20:
msh> access 1 range 192.168.0.10 192.168.0.20
Note
❒ The access range restricts the workstations from which printing is possible
by means of an address. If you do not need to restrict printing, make the
setting “0.0.0.0”.
❒ The entry is invalid if the start address is greater than the end address.
❒ Up to five access ranges can be specified. The entry is invalid if the target
number is omitted.
❒ When using a Web browser, telnet or SmartNetMonitor for Client/Admin,
you can use an IP address that has not been restricted by access control.
❖ Access Control Initialization 
msh> access flush
Note
❒ This restores the factory-default settings so that all access ranges become
"0.0.0.0".