Ricoh ap3850c Guia Do Utilizador

Página de 200
C
C-1
Importing Densitometer Measurements
This appendix describes Simple ASCII File Format, which can be used to import 
density measurements from measurement devices. To use your own measurement data 
from an alternate densitometer, record your individual readings in a text file and 
structure it as described below.
Simple ASCII Import File Format (SAIFF)
This format describes Status T measurement data and is for import into the 
ColorWise Pro Tools Calibrator. There are three possible file formats:
• 1D Status T density for EFI 34 patch page
• 1D Status T density for EFI 21 patch page
• 1D Status T density for other pages (maximum of 256 patches per ink)
The file format is ASCII and has no tabs. A single space or multiple spaces are used 
as delimiters. Blank lines are not allowed. Each line in the file represents four patches 
(C, M, Y, K) of a specific ink value. Comments may be on any line in the file, and 
these lines start with a pound sign (#) followed by a space. A line with a pound sign 
followed by any character other than a space has been reserved. Comments must be 
on an entire line by themselves.
Each line of data contains five values. The first number is the sequential patch number 
(for EFI 34 and EFI 21 pages) or the ink value percentage (for other pages). The 
following four values are the density values of C, M, Y, and K of the corresponding 
patch. Lines are ordered either by increasing sequential patch numbers or by increasing 
the ink percentage.
For Windows computers, the file extension must be .cm1. For Mac OS computers, the 
file type must be ‘TEXT’.
Measurement data in EFI 34 and EFI 21 are paper-relative. For other pages, if the first 
line corresponds to zero ink value, the Calibrator assumes that the measurement data is 
absolute and adjusts it to become paper-relative by subtracting the density values of the 
first line from the remaining patches.
Appendix C: 
Importing 
Densitometer 
Measurements