SPECIFICATIONS 
 
Width: 25 ¾” 
Height: 32 5/8” 
Depth: 23 7/8” 
Weight: 275 lbs. 
Flue size: 3” or 4” 
Hopper Capacity: Up to 140 lbs. 
(This can vary widely depending on pellet 
size, length, and diameter) 
EPA status: exempt 
Burn time: 1 lb. to 5.5 lbs. per hour 
BTU range: 8,200 to 55,000 
Approved installations: mobile home, alcove, 
conventional 
 
PREPARATION 
 
Factory packaging must be removed, and 
some minor assembly work is required prior 
to installation. Access to the rear of the stove 
is necessary. 
 
NOTE: Normally, your dealer will perform 
these functions. 
 
CLEARANCES 
 
The Big E has been tested and listed for 
installation in residential and mobile homes. 
FLOOR PROTECTION: Freestanding 
installations, minimum 30” wide by 32” deep. 
The stove must be placed on a continuous 
(grouted joints) noncombustible material such 
as ceramic tile, cement board, brick, 3/8” 
millboard or equivalent, or other approved or 
listed material suited for floor protection. 
THE MATERIAL(S) USED MUST HAVE, OR 
COMBINE TO HAVE, A MINIMUM 
INSULATIVE RATING OF ‘R1’. 
NOTE: ceramic tile, or any tile, requires a 
continuous sheet beneath to prevent the 
possibility of embers falling through to the 
combustible floor if cracks or separation 
should occur in the finished surface, this 
would include floor protection for Built-in 
raised hearths. Check local codes for 
approved alternatives. 
Clearances are measured from the sides, 
back and face (door opening) or stove body 
(refer to fig. 2).  
DO NOT USE MAKESHIFT MATERIALS OR 
COMPROMISES IN THE INSTALLATION 
OF THIS UNIT. 
INSTALL VENT WITH CLEARANCES 
SPECIFIED BY THE VENT 
MANUFACTURER. 
 
 
 
 
 
 
 
 
INSTALLATION 
FIGURE 1 
FLOOR PROTECTION 
(MINIMUM 30” W X 32” D) 
FIGURE 2