1. Remove the screws securing the terminal block access cover 
and the strain relief mounting bracket located on the back of the 
dryer upper corner.
2. Install a U.L. approved strain relief into the power cord entry hole 
of the mounting bracket. Finger tighten the nut only at this time.
3. Thread a U.L. Approved 30 Amp. Power cord, NEMA 10-30 Type
SRDT, through the strain relief.
4. Attach the power cord neutral (center wire) conductor to the silver 
colored center terminal on the terminal block. 
Tighten the screw securely.
5. Attach the remaining two power cord outer conductors to the 
outer brass colored terminals on the terminal block. Tighten both 
screws securely. Warning: Do not make a sharp bend or crimp
wiring/conductor at connections.
6. Reattach the strain relief mounting bracket to the back of the dryer 
with two screws. Tighten screws securely.
7. Tighten the screws securing the cord restraint firmly against the 
power cord.
8. Tighten the strain relief nut securely so that the strain relief 
does not turn.
9. Reinstall the terminal block cover.
Grounding:
This appliance must be connected to a ground metal,
Instruction:
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or
lead on the appliance.
3-Wire Cord Connections (USA only)
green
ground
screw
green
neutral
ground
wire
silver terminal
nut
tighten nut
to these threads
power cord
strain relief
mounting bracket