Newco iq2000p Guia De Utilização

Página de 12
- 4 -
Program and Service Mode Functions
Programming is done through the 4 hidden buttons located on the brewer faceplate under the display.
Prior to accessing the program or service mode you will need to attach a service template to the faceplate of the
unit in order to locate the buttons. Attach one of the self stick templates to the faceplate aligning it with the display
window edges and bottom border as shown in Fig 1 on page 2.
To enter either the Program or Service Mode:
Turn the main ON/OFF switch located on the lower left front of brewer column to the OFF position.
Depress and hold down both the Brew and Cancel Buttons located on the brewer face plate. (See Fig 1, Page 2).
Continue to hold while turning the ON/OFF switch to the ON position. The brewer display will indicate to please
wait as it initializes the program/service mode. Continue holding the brew and the cancel button until the brewer
enters the Program/Service main menu (approximately 5 seconds).
This is the Program/Service main menu. Use the Select key to choose either the
Program or Service mode. The program mode is used to set custom settings such
as brew times, buzzer type, tank temperature, enable power save or auto arm, etc.
The service mode is used for initial brewer fill, to display and clear error messages, to view total brew cycles, and
to view/reset the brew cycles since service.
An explanation of the various features for both modes is outlined in the following sections. Note that if at
any point after entering this menu the brewer detects that there has been no activity on the keypad for 1 minute it
will exit to the ready/standby mode. It will then be necessary to follow steps outlined above to return to the program
or service mode. If an option or feature has been changed without pressing enter prior to this occurring the change
will be lost.
Program Options
Table 1 - Summary of Program Mode Options/Features
Option
Program Options/Value Range
Factory
Setting
Description
Brew Time #1
10 Sec - 5 Min, 20 Sec
3:25
Dump valve open time for brew 1.
Brew #2 Enable
Yes, No
No
Optional second brew setting using hidden key.
Brew Time #2
10 Sec - 5 Min, 20 Sec
1:30
Dump valve open time for brew 2.
Buzzer Delay
10 Sec - 2 Min
1:00
Drain time from basket for brews 1 and 2.
Auto Arm Enable
Yes, No
Yes
Ensures optimum brew temperature.
Brew Time Remaining
Yes, No
Yes
Display time remaining during the brew cycle.
Temperature Setpoint
170
° 
F - 212
°
 F
205
Water holding temperature in tank.
Power Save Enable
Yes, No                    Time is factory set at
2 hours. May not be changed.
Yes
Drops tank temperature to 170
° 
F during
periods (2 hours) of non use to save energy.
Buzzer Type
Burst, None, Steady, Single Pulse, Double
Pulse
Steady
Signal for the completion of the brew cycle.
Keypad Beep Enable
Yes, No
Yes
Audible tone to ensure keys are fully
depressed.
Service Cycles
0 - 65535
500
Brew Cycles to run before displaying the Call
For Service Message for routine maintenance.
Exit Pgm/Srv Mode
Yes, No
N/A
Exit from programing mode to "Ready To
Brew".
This is the length of time which the dump valve will remain open to allow water to
flow over the coffee grounds. It is the active portion of the brew cycle. The Select
key may be used to choose a numeral in the displayed time to change and the "-"
or "+" keys may be used to change the selected numeral up or down as required to obtain the desired brew time.
Note that when setting brew time the display changes by 1 numeral each time the button is depressed. The
minimum time which may be programmed is 10 seconds and the maximum time is 5 minutes and 20 seconds.
Depress enter to save the programmed brew time.
This option allows a second brew function to be programmed thereby giving the
user multiple volume brewing capability. Brew #2 is the brew cycle which would be
Select Mode
Program      Service
Brew Time #1
                3:30
Brew #2 Enable
    Yes       No