Appendix
Environmental requirements
The Secure Router 4134 must operate within the specified tolerance limits
shown in the following table.
ATTENTION
Install the Secure Router 4134 in a restricted-access location. You must limit
access to the Nortel Secure Router 4134 to authorized service personnel only.
Ensure you allow 2 to 3 feet (0.61 to 0.91 m) of additional clearance around the
Secure Router 4134 for access to the cable connectors on the front and rear
panels.
Table 26
Environmental requirements
Parameter
Range
Operating temperature
0 to 40 C
Short-term temperature
–40 C to 70 C
Operating altitude
0–11 800 ft (0–3600 m)
Storage altitude
0–35 000 ft (0–11 000 m)
Operating humidity
0 to 90% R.H. (noncondensing)
Storage humidity
0 to 95% R.H. (noncondensing)
Vibration
Packaging and shipping – ISTA 2A Office
Vibration – GR-63-CORE Issue 3, Section 4.4.2
and 5.4.2
Acoustic Noise
GR-63-CORE Issue 3, section 4.6 & 5.6