Lowrance hds-5x Manual Do Utilizador

Página de 91
79
Troubleshooting
If your unit is not working, or if you need technical help, use the following 
troubleshooting section before contacting the customer service department.  
1. 
Check the power cable’s connection at the unit.
2. 
 Make sure the power cable is wired properly. The red wire 
connects to the positive battery terminal, black to negative 
or ground.
3. 
Check the fuse.
4. 
 Measure the battery voltage at the unit’s power connector. 
You will measure the two biggest pins. It should be at least 
10 volts. If it isn’t, the wiring to the unit is defective, the bat-
tery terminals or wiring on the terminals are corroded, or the 
battery needs charging.
1. 
 Electrical noise from the boat’s motor, trolling motor, or an 
accessory may be interfering with the sonar unit. Rerouting 
the power and transducer cables away from other electrical 
wiring on the boat may help. Route the sonar unit’s power 
cable directly to the battery instead of through a fuse block 
or ignition switch.
2. 
 Inspect  the  transducer  cable  for  breaks,  cuts,  or  pinched 
wires.
3. 
 Check the transducer and power connector. Make sure it’s 
securely plugged into the unit.
1. 
 Make sure face of the transducer is parallel to the ground. 
Refer to the installation manual for more information. 
2. 
 If  the  transducer  is  mounted  inside  the  hull,  be  sure  it  is 
shooting  through  only  one  layer  of  fiberglass,  that  it  is 
securely  bonded  to  the  hull  and  DOES  NOT  have  air 
Troubleshooting
Unit won’t turn on
Unit freezes, locks up, or operates erratically
Weak bottom echo, erratic readings or no fish returns