Safety Information
The unit must be connected to a grounded outlet to comply with European safety standards.
The socket outlet must be near the unit and easily accessible. You can only remove power from the 
unit by disconnecting the power cable from the outlet.
This unit operates under Safety Extra Low Voltage (SELV) conditions according to the IEC 950 
standard. The conditions are only maintained if the equipment to which it is connected also operates 
under SELV conditions.
The appliance coupler (the connector to the unit and not the wall plug) must have a configuration 
for mating with an EN60320/IEC320 appliance inlet.
France and Peru only
This unit cannot be powered from IT† supplies. If your supplies are of IT type, this unit must be 
powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary connection point 
labeled Neutral and connected directly to ground.
Power Cable
Use an AC power cable appropriate for your country. Check your local electrical codes and regulatory 
agencies for power cable requirements. The countries listed below have the following additional 
requirements:
USA and Canada
The cable set must be UL-listed and CSA-certified.
The minimum specification for the flexible cable is No. 18 AWG (1.5 mm
2
), Type SVT or SJT, 
3-conductor.
The cable set must have a rated current capacity of at least the amount rated for each specific 
product.
The AC attachment plug must be an Earth-grounding type with a NEMA 5-15P (10 A, 125 V) 
configuration.
Denmark
The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
Switzerland
The supply plug must comply with SEV/ASE 1011.
Argentina
The supply plug must comply with Argentinian standards.
NOTE
When using dual power supplies, make sure that each AC power supply attaches to an independent 
power source.
Fuse
This information only pertains to the Summit series of switches, with the exception of the Summit7i. 
The unit automatically adjusts to the supply voltage, and it is suitable for both 110 VAC and 200-240 
VAC operation.
To change the fuse in a Summit series switch: