INSTALLATION INSTRUCTIONS
FOR GROEN CASTER KIT ON
TS-9 STAND FOR TABLE TOP KETTLES
WARNING:
1.  WHEN INSTALLING ON A TABLE WITH GAS KETTLE, THESE CASTERS MUST BE 
 
INSTALLED WITH A GROEN GAS QUICK DISCONNECT SUPPLY KIT (GROEN PART 
 
#140144) OR A GAS HOSE WITH MAXIMUM LENGTH THAT IS LONGER THAN THE 
 
RESTRAINING CABLE.
2.  WHEN INSTALLING ON A TABLE WITH ELECTRIC KETTLE, LENGTH OF FLEXIBLE 
 
CONDUIT MUST BE LONGER THAN THE RESTRAINING CABLE.
INSTALLATION PROCEDURE-
     Figure 14                                                                 Figure 15
1.  Drill a 13/32” (0.406” or 9 mm) diameter hole through one of the rear legs of table 6” 
below the top of table as shown in Figures 14 and 15 above.
2.  Attach eyebolt, washers, lockwasher and nut to the table as shown in Figure 14.
Figure 16
3.  Anchor the restraining cable bracket to a secure structure. 
  One of the preferred locations is on the concrete floor using 
  anchor bolts (not  provided) as shown in in Figure 16.
GROEN CASTER KIT