Intermec 5055 Guia De Referência

Página de 216
5055 Programmer’s Software Kit Reference Manual
7-12
Code 39 (continued)
Use this table to help configure your 5055.
Code 39 Option
Bar Code Label
Decodes
Non-full ASCII
$%+A
/D/E+A
$%+A
/D/E+A
Full ASCII
$%+A
/D/E+A
No decode
$%a
Mixed-full ASCII
$%+A
/D/E+A
$%a
$%a
Syntax:
CBdata
Acceptable values for data must be three digits, corresponding to:
First digit:
0
Disabled
1
Enabled with no check digit
Second digit:
0
Ignored
1
Ignored
Third digit:
0
Code 39 non-full ASCII
1
Code 39 full ASCII
2
Code 39 mixed-full ASCII
Default:
Enable Code 39 Full ASCII with no check digit (111)
Scan:
To disable Code 39:
Disable Code 39
*$+CB000*
*$+CB000*
To enable Code 39 with non-full ASCII:
Enable Code 39, non-full ASCII
*$+CB110*
*$+CB110*
To enable Code 39 with full ASCII:
Enable Code 39; full ASCII
*$+CB111*
*$+CB111*