Intermec 2430 Guia Do Utilizador

Página de 374
Chapter 6—Configuration Command Reference 
162 
Trakker Antares 2400 Family System Manual 
Options for Configuration Commands Via Serial Port 
Option 
Description 
Disabled 
All data received through the serial port is treated as data. The terminal 
will not execute reader or configuration commands sent or encoded in 
the data. 
Enabled 
with TMF 
If the data is sent with the TMF (Terminal Message Format) header, the 
terminal will check for and execute reader or configuration commands 
received through the serial port. With TMF, you can execute reader and 
configuration commands or send and receive data about the current 
terminal configuration. 
Enabled 
without 
TMF 
The terminal will check for and execute all reader and configuration 
commands (i.e., Receive File reader command or Beep Volume change 
configuration command). 
 
 
 
Note: Before you can enable Configuration Commands Via Serial Port 
with or without TMF, you must configure the EOM command. 
 
Syntax: YTn.data 
where n is: 
COM1 serial port 
COM2 serial port (246X and 248X terminals only) 
COM3 serial port (242X terminals only) 
COM4 serial port (242X, 2455, and 248X terminals only) 
Acceptable values for data are: 
0 Disabled 
Enabled with TMF 
Enabled without TMF 
 
Default:  Enabled without TMF 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Serial 
Port 
 
Bar Codes:  To set the default for each serial port, scan these bar codes: 
COM1 Commands Via 
COM2 Commands Via  
Serial Port Enabled Without TMF 
Serial Port Enabled Without TMF 
*$+YT1.2* 
*$+YT2.2* 
*$+YT1.2* $+YT2.2* 
COM3 Commands Via 
COM4 Commands Via  
Serial Port Enabled Without TMF 
Serial Port Enabled Without TMF 
*$+YT3.2* 
*$+YT4.2* 
*$+YT3.2* *$+YT4.2*