Intermec 2430 Guia Do Utilizador

Página de 374
Chapter 6—Configuration Command Reference 
194 
Trakker Antares 2400 Family System Manual 
Power Management Tip: Intermec strongly recommends that you use the 
optimum inactivity timeout of 5 seconds to preserve power. 
 
Syntax: RYdata 
Acceptable values for data are: 
Radio never turns off 
1-51  Inactivity timeout in seconds multiplied by a value of 5 
where data=1 sets a timeout delay of 5 seconds, data=2 sets a timeout delay 
of 10 seconds, and so on, up to data=51 for a timeout delay of 255 
seconds. 
 
Default: 5 
seconds 
 
Menu System:  Main Menu > Configuration Menu > Communications Menu > Radio 
 
Bar Codes:  To set the default inactivity timeout to 5 seconds, scan this bar code: 
Default Inactivity Timeout 
*$+RY1* 
*$+RY1* 
 
Or:  To set the inactivity timeout: 
Scan this bar code: 
  Enter Accumulate Mode / Set Inactivity Timeout 
 
*+/$+RY* 
 *+/$+RY* 
Scan a numeric value for data from these bar codes: 
 
*0* 
*1* 
 *0* 
*1* 
 
*2* 
*3* 
 *2* 
*3* 
 
*4* 
*5* 
 *4* 
*5* 
 
*6* 
*7* 
 *6* 
*7* 
 
*8* 
*9* 
 *8* 
*9* 
Scan this bar code: 
  Exit Accumulate Mode 
 
*-/* 
 *-/*