Citel 6000 Guia Do Utilizador
PBXgateway
™
& EXTender
TM
6000 System Administrator’s Guide
128
MI Parameters
Address
(IP->LAN
->Address)
->Address)
Parameter Location:
Gateway/Remote ->Configuration->IP->Address
Description: The Internet Protocol (IP) Address
Usage: A 3-bit address used for IP connectivity. When assigned, the IP Address
identifies the PBXgateway and Remote on the network.
Example: 193.245.101.67
Dependencies:
Gateway/Remote ->Configuration->IP->Address
Description: The Internet Protocol (IP) Address
Usage: A 3-bit address used for IP connectivity. When assigned, the IP Address
identifies the PBXgateway and Remote on the network.
Example: 193.245.101.67
Dependencies:
• Must be assigned by the network administrator
• IP Address is required for unit management and RVP_IP connections.
• Must be an assigned static (fixed) address
• IP Address is required for unit management and RVP_IP connections.
• Must be an assigned static (fixed) address
See Also: Chapter 4 Setting IP Parameters.
Async Rate
Parameter Location:
Gateway/Remote ->Configuration->WAN->WAN_X->Async_Setup
Description: The asynchronous data transfer rate.
Usage: This parameter identifies the asynchronous data transfer speed of the
WAN port. This value must match the network device speed.
Note: This Async Rate typically would be left at the <default> setting of 115200.
Dependencies: N/A
Gateway/Remote ->Configuration->WAN->WAN_X->Async_Setup
Description: The asynchronous data transfer rate.
Usage: This parameter identifies the asynchronous data transfer speed of the
WAN port. This value must match the network device speed.
Note: This Async Rate typically would be left at the <default> setting of 115200.
Dependencies: N/A
Auto
Connect
Connect
Parameter Location:
Remote->Configuration->Port->Default or Port x
Description: If Enabled, the phone ports automatically connect when the
PBXgateway and Remote units are powered up. This feature also includes a
retry timer with backoff. This means that the unit will wait a few seconds between
retries and will only try and connect up to a minute before it stops.
Usage: No need to press “1” on Remote phone to connect.
Dependencies: Remote unit only
Remote->Configuration->Port->Default or Port x
Description: If Enabled, the phone ports automatically connect when the
PBXgateway and Remote units are powered up. This feature also includes a
retry timer with backoff. This means that the unit will wait a few seconds between
retries and will only try and connect up to a minute before it stops.
Usage: No need to press “1” on Remote phone to connect.
Dependencies: Remote unit only