Panasonic AK-HC910 Manual Do Utilizador
21
PED,GAMMA,FLARE
M PED :+027
R PED :+000
B PED :+000
M GAMMA :0.45
R GAMMA :+00
B GAMMA :+00
R FLARE :010
G FLARE :000
B FLARE :017
GAMMA :ON
FLARE :ON
R PED :+000
B PED :+000
M GAMMA :0.45
R GAMMA :+00
B GAMMA :+00
R FLARE :010
G FLARE :000
B FLARE :017
GAMMA :ON
FLARE :ON
°°
°°
Setting of Menu Items
! Maintenance menu
2 Pedestal, gamma, flare adjustment
menu
M PED: Master pedestal can be
adjusted only by turning the control
panel VR.
The R, G, B pedestal can be totally
adjusted.
adjusted only by turning the control
panel VR.
The R, G, B pedestal can be totally
adjusted.
R, B PED: R, B pedestal adjustment.
Besides the master pedestal
adjustment, R, B pedestal can be
independently adjusted. It is not related
to DATA REF. The numeral display
after normal ending of ABB is “0” for
both of R, B.
Besides the master pedestal
adjustment, R, B pedestal can be
independently adjusted. It is not related
to DATA REF. The numeral display
after normal ending of ABB is “0” for
both of R, B.
M GAMMA: Master gamma adjustment.
The R, G, B gamma can be totally
adjusted.
The R, G, B gamma can be totally
adjusted.
R, B GAMMA: R, B gamma adjustment.
Besides the master gamma adjustment,
R, B gamma can be independently
adjusted.
Besides the master gamma adjustment,
R, B gamma can be independently
adjusted.
R FLARE: R flare adjustment
G FLARE: G flare adjustment
B FLARE: B flare adjustment
GAMMA: Gamma ON/OFF setting