1-36 
test-failtimes 
Syntax 
test-failtimes times 
undo test-failtimes 
View 
remote-ping test group view 
Parameters 
times: Number of times of consecutive test failure, in the range of 1 to 15. 
Description 
Use the test-failtimes command to configure the number of consecutive times a remote-ping test fails 
before the switch sends out a trap message.  
Use the undo test-failtimes command to restore the default.  
By default, the switch sends a trap about test failure each time when a test fails. 
Examples 
# Configure the switch to send out a trap message after an ICMP test fails for three consecutive times.  
<Sysname> system-view 
System View: return to User View with Ctrl+Z 
[Sysname] remote-ping administrator icmp 
[Sysname-remote-ping-administrator-icmp] test-type icmp 
[Sysname-remote-ping-administrator-icmp] test-failtimes 3 
timeout 
Syntax 
timeout time 
undo timeout 
View 
remote-ping test group view 
Parameters 
time: Timeout time for one probe, in the range of 1 to 60, in seconds.  
Description 
Use the timeout command to set the timeout time for a probe.  
Use the undo timeout command to restore the default value. 
The remote-ping client starts the probe timer after sending a test packet. If the remote-ping client 
receives no response before the timer expires, it considers that the current probe has timed out. 
By default, the probe timeout time is 3 seconds.