Elmo dvr v5.01 Manual Do Utilizador

Página de 153
To setup all connected cameras, do the following:
1. Check the Enable checkbox for all connected cameras. The numbers correspond with the physical BNC connectors
in the back of the DVR.
Note
This feature is NOT available on ELMO DVR
Remote.
2. Assign a Camera ID to any camera that can be controlled by a user - a P/T camera. Cam IDs are assigned in order
to distinguish between the different P/T cameras connected to the same parallel connection. Most Speed Domes have
their Cam ID assigned by dip-switches in the back of the camera. Fixed cameras do not have a Cam. ID.
Note
The BNC connector number does not have
to match the Cam. ID number.
3. Label the cameras for easy identification (e.g. Front Door)
4. Enter the Sensor number to be associated with the specific camera. If the specific sensor is triggered, that camera
will begin recording (see Sensor Setup, Schedule Setup). In the above example, if Sensor 2 is triggered, Camera 1
(Front Door) will start recording.
5. In the Motion field associate the current camera with one or more cameras. When motion is detected on an asso-
ciated camera(s), the current camera will start recording. Motion detection has to be configured and Schedule Setup
has to be set to Motion recording for the associated camera(s). (see Motion Setup, Schedule Setup). In the above
example, if the motion occurs on Camera 3 (Back Door), Camera 1 (Front Door) and 4 (Warehouse) will begin recording.
6. Check the P/T/Z (Pan-Tilt-Zoom) checkbox for cameras supporting the P/T feature
Note
This feature is NOT available on ELMO DVR
Remote.
7. Choose the correct camera make and model (Type) for the PTZ cameras from the list provided
8. Check the Auto-Pan (A/P) checkbox for the installed PTZ cameras. This feature allows the PTZ camera to return
to the programmed auto pan after a user adjusts the PTZ settings remotely and exits the program without returning
to the original settings.
9. Assign Dwell Time for the A/P setting. This is the time that will pass before the Auto-Pan (A/P) will be activated.
In the above example, Camera 1 will return to the original pan after 20 seconds.
3.2. Hardware Setup - Sensor Setup
3.2.1. Overview
In the Sensor Setup the user can configure the connected sensors. Sensors are set as NC or NO (NC = Normally Closed;
NO = Normally Open).
An NC sensor is any sensor with an electrical circuit closed by default.
E.g. - a sensor on a closed door. When the door is opened, the electrical circuit is broken and the sensor is triggered.
14
ELMO DVR User Manual v5.01
Hardware Setup - Sensor Setup
ELMO DVR Server