3. Define the Frequency of Call Out in a 24-hour period. If motion is detected or a sensor is triggered, the
ELMO DVR will send an alert either to the phone number or to the IP address. The Frequency of Call Out is the max-
imum allowed number of phone call alerts per day. In the example below, the ELMO DVR will only dial out once every
24 hours. If the sensor is triggered more than once in 24 hours, one phone call will be made, but the rest of the oc-
currences will be ignored. The maximum number of phone call alerts that can be send per day is 9999. Note that this
number does not limit the maximum number of alerts sent to the IP address (Remote Monitor).
4. In the Emergency Setup, define which cameras/sensors will cause an alert. In this example, if the motion is
detected on Cameras 1,3 and 7 or if the Sensors 2-4 are triggered, an alert will be sent.
5. Choose Emergency Phone Numbers to receive an alert via telephone. The first number is the default
number for all emergency communications. The second number is a backup number in case the first one fails. These
numbers are also used by the Intelli-Guard™ for Auto Dial-Out.
6. Choose an Emergency IP Address to receive an alert on the Emergency Monitor software installed on the
same or another system.
7. Set Transfer Time. Transfer Time specifies the time in seconds between the detected motion (triggered sensor)
and the alert transmission. In the example above, the alarm will be sent to the Emergency IP address 90 seconds
after the sensor has been triggered.
3.11. Server Information
3.11.1. Overview
The Server Information tab permits configuring the Server, as well as obtaining information about the Server, the ELMO
DVR, and the exporting/importing settings. Setting the system time is also done on this tab.