6.3  NomadLink / Ethernet  
network setup 
The amplifier includes, as a standard feature, internal 
facilities for the NomadLink monitoring and control 
network. All features of the NomadLink network are 
accessible via a PC running Lab.gruppen’s proprietary 
DeviceControl software. A single rackspace NLB 60E 
NomadLink Bridge & Network Controller accepts the 
TCP/IP data stream from the computer and converts it 
to the NomadLink protocols. Even when no computer 
is connected, the NLB 60E can initiate stand-alone 
power on/off and muting functions, as well as report 
any fault or warning conditions.
The  PC  is  connected  to  the  NLB  60E  using  a  
standard Ethernet interface and a crossed Cat-5 cable  
(peer-to-peer setup). If a HUB or switch is in the 
network, standard “straight” Cat-5 cables must be 
used. The front and rear Ethernet connections on 
the NLB 60E can be used individually, but only one 
PC at a time running DeviceControl can access the 
subnet.
Many newer laptop computers will allow 
peer-to-peer connection with the NLB 60E 
using a standard “straight” Cat-5 cable in-
stead of a crossed Cat-5 cable.
The default fixed TCP/IP address of the NLB 60E is 
192.168.1.166. The subnet mask is 255.255.255.0. 
For  further  details,  please  refer  to  instructions  
supplied with the NLB 60E unit.
The NomadLink connections use standard “straight” 
Cat-5/RJ45 equipped cables. For a safer mechanical 
connection it is possible to use Neutrik EtherCon 
“XLR-type” housings on the cables.
US National Differences cl.16.3 requires 
that NomadLink network cables must be 
rated VW-1.
The OUT port from the NLB 60E must be connected 
to the IN port of the first amplifier. The OUT port 
from the first amplifier in turn connects to the next 
amplifier’s IN port to form a daisy-chain The OUT 
port on the last amplifier is connected to the IN port 
on the NLB 60E to close the loop.
There  are  electrical  limitations  to  cable 
lengths on a NomadLink network, both in 
terms of total cable length in the loop and 
between  any  two  devices.  Read  the  
Operation and Performance chapter in this manual, 
or the instructions supplied with the NLB 60E, to 
ensure  the  network  is  configured  within  these  
parameters. 
Although the network will function as an 
open loop under most circumstances, it is 
strongly recommended that the loop be 
closed by connecting the last amplifier’s 
OUT port to the NLB 60E’s IN port. Doing so will 
improve redundancy and communication speed.
External contact closures and 24 V low/high triggers 
can be connected to the GPI connectors on the NLB 
60E for control of fire-alarm systems or external 
power sequencers. For more details read the instruc-
tions supplied with the NLB 60E.
6  QUICK GUIDE OVERVIEW
SPEAKER OUTPUTS
BALANCED INPUTS
CH D
CH D
CH C+D
CH 
CH B
CH A+B
CH C
CH A
XLR
PIN 1-SCRN
PIN 2-POS
PIN 3-NEG
44dB 
41dB 
38dB 
35dB 
32dB 
29dB 
26dB 
23dB 
150V 
121V 
101V 
83V 
70V 
56V 
47V 
38V 
BRIDGE
   1+:+
   2- : -
1+ CH D+
1-  CH D-
1+ CH C+
1-  CH C-
2+ CH D+
2-  CH D-
1+ CH B+
1-  CH B-
1+ CH A+
1-  CH A-
2+ CH B+
2-  CH B-
Ser. N:o
Removed!
WIRING
NORMAL: CLASS 2
BRIDGED: CLASS 3
Must be grounded/earthed
Made in Sweden 
200-240V      50-60Hz :2500W
FP 10000Q
IN   OUT
NOMADLINK
IN   OUT
NOMADLINK
NOMADLINK
IN     OUT
ETHERNET
GENERAL
PURPOSE
INPUT, GPI
ETHERNET
"Crossed" RJ45 cable: 
Between NLB 60E and PC. 
"Straight" RJ45 cable: 
Between Ethernet switch or hub and NLB 60E.
"Straight" RJ45 cables: 
Between NLB 60E and amplifiers, and from 
amplifier to amplifier in a subunit.
NOTE: Connection can be made to either 
the front or rear panel or the NLB 60E. 
Although two computers may be connected 
to the NLB 60E simultaneously, only one is 
allowed access to the subnet at a time.