28  FP+ Series Operation Manual 
8  APPENDIX
8.4    Current draw and Thermal dissipation specifications 
The following tables contain information on measured current consumption as well as calculated heat dissipa-
tion during normal operation(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
FP 13000
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby, with remote power off via NomadLink
0
0
0
0
0
Powered on, idling
129
0
129
440
111
Amp (I)
Watt
Pink noise (1/8 
rated power)
16 
Ω / Ch.
1200 x 2
10.6
5.3
678
300
378
1289
325
32 
Ω / Bridged
2400 x 1
Ω / Ch.
2350 x 2
16.2
8.1
1083
588
495
1690
426
16 
Ω / Bridged
4700 x 1
Ω / Ch.
4400 x 2
26.5
13.2
1856
1100
756
2578
650
Ω / Bridged
8800 x 1
Ω / Ch.
6500 x 2
37.8
18.9
2536
1625
911
3109
783
Ω / Bridged
13000 x 1
Pink noise (1/4 
rated power) 
*3)
16 
Ω / Ch.
1200 x 2
16.0
8.0
1037
800
237
807
203
32 
Ω / Bridged
2400 x 1
Ω / Ch.
2350 x 2
27.2
13.6
1840
1567
273
933
235
16 
Ω / Bridged
4700 x 1
Ω / Ch.
4400 x 2
48.3
24.1
3419
2933
486
1659
418
Ω / Bridged
8800 x 1
Ω / Ch.
6500 x 2
58.0
29.0
4243
3250
993
3390
854
Ω / Bridged
13000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Nema L5-30P Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and 
specifi ed here is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum power before amplifi er protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated 
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be 
tripped even if operation is in excess of max. ratings.
FP 7000
Level
Load
Rated Power
Line Current *2)
Watt *1)
Thermal dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby, with remote power off via NomadLink
0
0
0
0
0
Powered on, idling
92
0
92
316
80
Amp (I)
Watt
Pink noise (1/8 
rated power)
16 
Ω / Ch.
730 x 2
6.8
3.4
411
183
229
781
197
32 
Ω / Bridged
1460 x 1
Ω / Ch.
1450 x 2
10.8
5.4
692
363
329
1123
283
16 
Ω / Bridged
2900 x 1
Ω / Ch.
2800 x 2
17.4
8.7
1176
700
476
1625
409
Ω / Bridged
5600 x 1
Ω / Ch.
3500 x 2
22.0
11.0
1518
875
643
2195
553
Ω / Bridged
7000 x 1
Pink noise (1/4 
rated power) 
*3)
16 
Ω / Ch.
730 x 2
19.6
9.8
800
487
313
1070
270
32 
Ω / Bridged
1460 x 1
Ω / Ch.
1450 x 2
33.3
16.6
1455
967
489
1667
420
16 
Ω / Bridged
2900 x 1
Ω / Ch.
2800 x 2
39.4
19.7
2705
1867
838
2860
721
Ω / Bridged
5600 x 1
Ω / Ch.
3500 x 2
39.4
19.7
3088
2333
754
2574
649
Ω / Bridged
7000 x 1
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
30 A, Nema L5-30P Twist lock
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and 
specifi ed here is what is known as the “Active Power” of the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum power before amplifi er protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated 
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be 
tripped even if operation is in excess of max. ratings.