Bunn H5E Guia Do Utilizador

Página de 22
19
SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across the terminals of the tank 
heater with a voltmeter. Connect the dispenser to 
the power source. The indication must be:
 
a.) 100 to 120 volts ac for 100 to 120 volt models 
or
 
b.) 200 to 240 volts ac for 200 to 240 volt models
 
or
 
c.) 230 volts ac for 230 volt models.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank 
heater.
4.  Remove the tank heater from the tank lid and inspect 
it for cracks in the sheath.
If the sheath shows no sign of damage, proceed to #5.
If the sheath is damaged, replace the tank heater.
5.  Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reinstall the tank 
heater. The tank heater is operating properly.
If  continuity  is  not  present  as  described,  replace  the 
tank heater.
FIG. 12 TANK HEATER
FIG. 13 TANK HEATER WIRING
BLK to Limit 
Thermostat
BLU to Triac Assy
P1780
P1772
Removal and Replacement:
1.  Remove the wires to the tank heater.
2.  Remove  the  8-32  nuts  from  the  tank  heater 
flange.
3.  Remove the tank heater.
4.  Inspect the tank heater gasket and replace if neces-
sary.
5.  Securely install the new tank heater. Be certain of 
a watertight seal.
6.  Reconnect the wires, FIG. 13.
10420 091902