sync Commands
11-8
Cajun A500 ATM Switch User Guide
sync setsync
Purpose
The 
sync setsync
 command enables you to set the sync card parameters for the Cajun 
A500. After you enter the command, the system displays a set of options. Enter the 
parameters you want for each of the options and press  Return. The options are:
U Timing Reference Priorities
U External reference Type
U DS1 Framing Type
U Wait Time to Restore 
U OCN Port/Line TMG References 
Syntax
sync setsync 
Arguments
This command requires the following argument(s):
Timing Reference 
Priorities
Enter the timing reference priority. The clock reference with the 
highest priority is used to lock the timing. In case of failure, the next 
highest priority source is used. The valid range is 4 to 0 (4 = highest, 1 
= lowest, 0 = disabled). 
External Reference Type
Enter the external reference type. This refers to the type of signal 
present used for the external references. It can be either DS1 or E1. 
Note: 
These are standard communication terms.
ODS1 Framing Type
Enter the framing type. This option is based on the type selected for 
the external reference type. 
• DS1--> Can be either SF (superframe) or ESF (extended 
superframe). 
• E1 --> framing or no framing.
Wait Time to Restore
When a higher priority clock reference returns, this is the time to wait 
before restoring this clock source as the current reference. This wait 
time ensures the source is stable before using it as the clock source.
OCN Port/Line TMG 
References
The Primary and Secondary OC-N references are selected from any of 
the 32 ports on the Cajun A500.