Avaya P550 Guia De Referência
Temperatures
19-6
Cajun P550/P220 Command Line Interface Reference Guide
Table 19-5.
Parameters, Keywords, Arguments
This example sets the backplane-sensor warning upper temperature to 44° (Celsius).
Cajun(configure)# set temperature backplane-sensor warning upper
44
Name
Definition
supervisor-slot|
backplane-sensor|
cpu-sensor|probe
backplane-sensor|
cpu-sensor|probe
These parameters indicate which component of the switch
is of interest.
is of interest.
warning
Warning is a required parameter indicating that a warning
limit is being modified.
limit is being modified.
upper|lower| low-limit
One of these parameters is required to indicate whether
the upper, lower, or low-limit warning is being changed.
the upper, lower, or low-limit warning is being changed.
temperature
Temperature is a required parameter and when the switch
measures this value on this component, it shuts itself down
in order to prevent either inconsistent behavior or damage
to itself or surrounding equipment. The command checks
the entered temperature value and ensures that the
temperature being set is not above 127, and not below -128
degrees.
measures this value on this component, it shuts itself down
in order to prevent either inconsistent behavior or damage
to itself or surrounding equipment. The command checks
the entered temperature value and ensures that the
temperature being set is not above 127, and not below -128
degrees.