Appendix D: Applications and Switch Administration
DEFINITY
 Communications System
DEFINITY High Speed Link
Page  D-28
User´s Guide
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
Generic 2 System Administration
For data calls that originate on a Generic 2, the tone detector must
be administered.  This is done by creating a special trunk group.  If
this is the first data application on the switch, then this trunk
group must be created using PROC 100, Word 1 (Screen D-13).  In
this case the trunk group is 100.
d
trunk group.  The following fields must be populated as
indicated:
Field 1 (Trunk Group): 
100.  This is the trunk group for the
tone detectors.
Field 6 (Trunk Type): 
100.  To indicate that this is a tone
detector trunk group.
Once this trunk group is created, no further administration for
tone detectors is needed for additional stations.
ENHANCED MODE - PROCEDURE:  100, WORD: 1 
1. 
Trunk Group: [100] 
DIAL ACCESS CODE/TRUNK ID CODE 
2.  Digit 1: [1] 
3.  Digit 2: [0] 
4.  Digit 3: [0] 
5.  Digit 4: [-] 
6. Trunk Type: [100] 
7. 
Dial Access Restriction: [0] 
8.  Personal CO Line Appearance: [0] 
9. Public Network Access/Egress: [0] 
DISPLAY ONLY 
10.  Signaling Type: [0] 
cc
c
c
c
c
c
c
c
c
c
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
cc
c
c
c
c
c
c
c
c
c
bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
SCREEN D-13
Generic 2 Tone Detector Administration
d
PROC 150 
is required to install the tone detector circuits.