KYOCERA FS-2000D Guia De Utilização

Página de 146
Computer Interface 
ADVANCED OPERATION GUIDE
4-7
RS-232C Protocol
Parameters of the RS-232C Protocol 
A protocol is a set of rules followed by various devices to send or receive 
data. The parameters of the RS-232C protocol are stored in the battery-
powered memory of the printer. You can verify these parameters on the 
status printout as marked by the following identifications:
H1: Baud rate
H2: Number of data bits
H3: Number of stop bits
H4: Parity
H5: Protocol logic
H6: Buffer-nearly-full threshold
H7: Buffer nearly-empty threshold
H8: Received data buffer size
The parameters can be changed from the printer operation panel. To 
change the value for the serial interface parameters, refer to Changing 
Serial Interface Parameters on page 2-31
.
This following section outlines the parameters and their values you can 
select on the operation panel:
H1: Baud rate
The factory setting is 96 (9600 baud).
H2: Number of data bits
7 or 8. The factory setting is 8.
H3: Number of stop bits
1 or 2. The factory setting is 1.
Parameter value
Baud rate
12
1200
24
2400
48
4800
96
9600
19
19200
38
38400
57
57600
11