Eaton PW101MI1U403 Manual Do Utilizador
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999
2
Option 1
A1 = 120V/15A input, 15A outlets
A2 = 120V/20A input, 20A outlets
A1 = 120V/15A input, 15A outlets
A2 = 120V/20A input, 20A outlets
B1 = 240V/15A input, 15A outlets
B2 = 240V/20A input, 20A outlets
B3 = 240V/20A input, 15A outlets
C1 = 120V/30A input, 15A outlets
C2 = 120V/30A input, 20A outlets
F1 = 240V/30A input, 15A outlets
F2 = 240V/30A input, 20A outlets
F3 = 240V/30A input, 15A outlets
G1 = 120/240V/30A input, 5-15Rs
H1 = 120/240V/30A input, 6-15Rs
J1 = 120/240V/30A input, 5-15/6-15Rs
B2 = 240V/20A input, 20A outlets
B3 = 240V/20A input, 15A outlets
C1 = 120V/30A input, 15A outlets
C2 = 120V/30A input, 20A outlets
F1 = 240V/30A input, 15A outlets
F2 = 240V/30A input, 20A outlets
F3 = 240V/30A input, 15A outlets
G1 = 120/240V/30A input, 5-15Rs
H1 = 120/240V/30A input, 6-15Rs
J1 = 120/240V/30A input, 5-15/6-15Rs
Option 2
F = Filter
N = No Filter
F = Filter
N = No Filter
Option 6
09 = 9 foot power cable
15 = 15 foot power cable
09 = 9 foot power cable
15 = 15 foot power cable
Option 5
0 = no current meter
1 = current meter
0 = no current meter
1 = current meter
Option 4
S = Straight blade Plug
L = Locking Plug
S = Straight blade Plug
L = Locking Plug
Option 3
S = Straight blade outlets
L = Locking outlets
S = Straight blade outlets
L = Locking outlets
T 9 8 2
-
-
-
For option descriptions see pages 3 and 4
Optional cable restraint system
KIT-CABLRES-03 (Color Black)
KIT-CABLRES-03 (Color Black)
T982 “Design Your Own” part number guide
Optional Current Monitoring
Visit www.pulizzi.com/stock for stock configurations.
RACK MOUNTING
•
19” X 1.72” (1U) x 7.0”
•
Width is 17.5” without mounting ears
•
16 gauge steel, color black
•
Detachable mounting brackets allow for
several mounting options
several mounting options
POWER INPUT
•
Power cable with plug is attached to unit
through the rear panel cable grip
through the rear panel cable grip
12 NEMA OUTLETS
•
Straight blade or twist lock are optional
•
Optional cable restraint system with
cable management. P/N: KIT-CABLRES-03
EMI/RFI FILTERING (Optional)
•
Filtering is both Common Mode (Line -
Ground) and Differential Mode (Line - Line)
Ground) and Differential Mode (Line - Line)
SPIKE/SURGE SUPPRESSION
•
Transient voltage surge suppression
prevents damage due to voltage
prevents damage due to voltage
fluctuations
•
Metal Oxide Varistors (MOVs) are
utilized line to line (or neutral)
•
MOVs provide long life protection while
withstanding large transients with little
degradation
withstanding large transients with little
degradation
CURRENT MONITORING (Optional)
•
Front panel display shows current draw
of connected equipment
of connected equipment
•
Two digit display shows current from
0-30 amps with +/- 1 amp accuracy
0-30 amps with +/- 1 amp accuracy
•
Monitor will help to prevent system
overload and ease installation
INDICATOR LIGHT
•
One blue LED indicator light per
circuit breaker
circuit breaker
•
Light illuminates when the circuit
breaker is on and power is present
at the input
breaker is on and power is present
at the input
BRANCH CIRCUIT PROTECTION
•
Electromagnetic circuit breakers to prevent
temperature from affecting the trip point
temperature from affecting the trip point
•
UL listed branch circuit breakers are
provided where required by UL 60950-1
standards
standards
T982C1 Front
T982C1 Rear