Commercial Display RS-232 Protocol
 
004 : YPbPr 
005 : S-Video 
Monitor ID 
3D 
001 ~ 026  
 
 
Number  
40 
000 ~ 009  
 
 
Key Pad 
A  
41 
000 : POWER 
 
 
001 : SOURCE 
002 : MENU/EXIT 
003 : UP 
004 : DOWN 
005 : LEFT 
006 : RIGHT 
007 : MUTE 
Remote Control  
B  
42 
000: Disable 
Disable: RCU has no effect on 
HDTV. 
001: Enable  
Enabled: RCU controls the 
HDTV. This is the power up 
default on the HDTV. 
002: Pass through 
Pass through: RCU has no 
effect on HDTV and all RCU 
command codes are transmitted 
to FC via the RS232 port. See 
page 15 for more details 
Key Pad 
43 
000: Disable 
Disable: Key Pad have no 
effect on HDTV. 
001: Enable 
Enabled: Key Pad control the 
HDTV. This is the power up 
default on the HDTV. 
Factory reset 
7E 
Rests HDTV to factory setting 
 
 
 
 
 
4.2 
Get-Function Listing  
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format 
consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte 
is always = 00. 
 
Get-Function description:  
Length:  
Total bytes of message = 5 ASCII (35H), excluding “CR” 
Command:  
Get-Function command code: One byte ASCII code  
Value[1~3]:  Always = 000 
 
Get-Function format from PC to LCD (ASCII) 
Name  
Length   Command  Value1   Value2   Value3   CR  
Byte Count  
5  
1 Byte 
0  
00D 
Bytes order 
 
Monitor shall response to Get-Function with the following packet format: 
 
LCD Monitor response packet format: 
Name  