Viewsonic CDE4803 Manual Do Utilizador
33
Example2: Get Brightness from TV-05, but the Brightness command ID is error and it is NOT in the
command table.
Send (Hex Format)
Send (Hex Format)
Name
Length
ID
Command
Type
Command Value1
Value2
Value3
CR
Hex
0x38
0x30
0x35
0x67
0XD3
0x30
0x30
0x30
0x0D
Reply (Hex Format)
Name
Length
ID
Command
Type
CR
Hex
0x34
0x30
0x35
0x2D
0x0D
Get function table:
Get Function Length
ID
Command
Type
Command
Value Range
Comments
Code (ASCII)
Code (Hex)
(Three ASCII bytes)
Get-Contrast
8
g
a
61
000 ~ 100
Gets Contrast value
Get-Brightness
8
g
b
62
000 ~ 100
Gets Brightness value
Get-Sharpness
8
g
c
63
000 ~ 100
Gets Sharpness value
Get-Color
8
g
d
64
000 ~ 100
Gets Color value
Get-Tint
8
g
e
65
000 ~ 100
Gets Tint value
Get-Volume
8
g
f
66
000 ~ 100
Gets Volume value
Get-Mute
8
g
g
67
000: OFF (unmuted)
001: ON (muted)
Gets Mute ON/OFF
status
Get-Input select
8
g
j
6A
000~
See Set-function table
Get-Power
status : ON/
STBY
8
g
l
6C
000: STBY
001: ON
Get-Remote
control
8
g
n
6E
000 : Disable
001 : Enable
002 : Pass through
Get-Power Lock
8
g
o
6F
000 : Unlock
001 : Lock
Get-Button Lock
8
g
p
70
000 : Unlock
001 : Lock
Get-Menu Lock
8
g
q
71
000 : Unlock
001 : Lock
Get-ACK
8
g
z
7A
000
This command is
used to test the
communication link.
Get-Thermal
8
g
0
30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
For specific models
only
Get-Power on/
off log
8
g
1
31
000
(See below note)
For specific models
only
Get-Date
8
g
2
32
000
(See the Set-Date
command)
For specific models
only
Get- Time
8
g
3
33
000
(See the Set-Time
command)
For specific models
only
NOTE: