Minute Man Entrust ETR1500 Folheto

Códigos do produto
ETR1500
Página de 2
Specifications
ETR500
ETR700
ETR1000
ETR1500
Maximum load (VA/Watts)
500VA/300W
700VA/420W
1000VA/600W
1500VA/900W
Battery rating
(1) 12V/5AH
(1) 12V/7AH
(2) 12V/7AH
(2) 12V/9AH
Unit weight (lbs.)
13.23 lb (6.0kg)
15.44 lb (7.0kg)
28.89 lb(13.1kg)
29.33 lb (13.3kg)
©  Copyright  2007,  Para  Systems,  Inc.    Product  specifications  are  subject  to  change 
without  notice.  Minuteman  and  Minuteman  Platinum  Protection  Plan  are  registered 
trademarks and Entrust and SentryPlus are trademarks of Para Systems, Inc.  
PN-34
000313 
- 6-07
From Para Systems, Inc.
Power Technologies
Para Systems, Inc./Minuteman UPS 
1455 LeMay Drive Carrollton, TX 75007  U.S.A. 
Phone 800.238.7272  +1 972.446.7363  Fax +1 972.446.9011
Minuteman® Entrust Series Line Interactive UPS Specifications
www.minutemanups.com•www.sizemyups.com • www.sizemypdu.com • www.comparemyups.com
Input capacity
8 Amps
10 Amps
12 Amps
Unit dimensions (H x W x D)
10.8 x 3.43 x 10.9 in
(274.4 x 87 x 277.2 mm)
10.8 x 3.43 x 16.4 in
(274.4 x 87 x 412.5 mm)
G
eneral
 s
pecifications
Topology
Single boost/buck line interactive, simulated sine wave
Warranty
(USA and Canada only) 3-year limited warranty, Platinum Protection Plan
2-year warranty on battery
ac i
nput
Number of phases
Single (2W + G)
Input voltage (Acceptable input voltage)
120VAC (0 - 160VAC)
Input voltage range (Normal mode)
90 - 150VAC
DC start capability 
Yes, (defaults to 60Hz)
Power cord
NEMA 5-15P on a 6-ft. power cord
Surge energy rating
320 Joules
Let through
5%, 6kV ring wave ANSI C62.41-1991 Cat 3
Response time
0 ns normal mode, < 5 ns common mode
AC leakage current
 <1 mA
ac o
utput
 (n
ormal
 m
ode
)
Load power factor
0.6
Output frequency
Same as Input
Short circuit protection
Re-settable circuit breaker and electronically limited
Overload capability
110% - 5 minutes ≥120% - immediate shutdown
Output voltage regulation
120VAC: -12.5% to +8.4%
Waveform
Same as Input
Boost mode voltage(Buck mode voltage)
Nominal +16% (Nominal -14%)
Line mode voltage range
105 - 130VAC
Efficiency
Normal mode > 90%
ac o
utput
 (B
attery
 m
ode
)
Output voltage
Nominal 120VAC
Waveform
Stepped sine wave (simulated sine wave)
Battery mode voltage regulation
Nominal ± 6% until LBW
Transfer time
6-10 ms
Output frequency & regulation
50/60Hz ± 0.5Hz (Unless synchronized to utility)
Battery runtime (full load/half load)
≥ 2 minutes / ≥ 9 minutes
Short circuit protection
Active electronic (current limit)
B
atteries
Replacement
Hot swappable
Recharge time
8 hours to 90% after full load discharge
e
nvironmental
Operating temperature 
32°F to 104°F (up to 5,000 ft above sea level  (0°C to 
+40°C (up to 1,500 meters above sea level)
Operating elevation
32°F to 95°F (5,001-10,000 ft above sea level (0°C to 
+35°C (1,501 to 3,000 meters above sea level))
Storage temperature/ Relative humidity
5°F to 113°F (-15°C to +45°C) / 0 - 95% non-condensing
m
echanical
Line protection (data/phone)
Single line input/output (RJ-45/RJ-11)
Outlets
4 - surge only outlets    4 - battery & surge with (2) transformer blocks
Monitoring software
Includes SentryPlus software
Communications
USB
Safety and environment
UL1778, cUL (CSA 22.1), CE, FCC Class B RoHS