KitchenAid 30'' Slow Cook Warming Drawer, Architect® Series II Guia Da Instalação

Página de 12
3
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
Phillips screwdriver
Drill
1
³⁄₈" (3.5 cm) hole saw
Parts supplied
4 - #8-18 x 
⁵⁄₈" screws
Lens (for panel ready models)
Check local codes. Check existing electrical supply. See 
“Electrical Requirements.”
It is recommended that all electrical connections be made by a 
licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cutout dimensions that are shown must be used. Given 
dimensions provide minimum clearance with warming drawer.
Recessed installation area must provide complete enclosure 
around the recessed portion of the warming drawer. 
Grounded electrical supply is required. See “Electrical 
Requirements” section.
Electrical supply outlet should be located in the rear wall on 
the upper right-hand side of the cutout or in an adjacent 
cabinet. The outlet must be recessed. If the electrical outlet is 
located in an adjacent cabinet, a 1
³⁄₈" (3.5 cm) minimum 
diameter hole should have been drilled in the back of the 
cutout or support surface to pass the power supply cord 
through to the outlet.
Warming drawer support surface must be solid, level and 
flush with bottom of cabinet cutout.
Warming drawers with oiled bronze, black glass, and white 
glass panels are approved for indoor use only.
For best performance results, make sure the warming drawer is 
leveled before completing installation. There is no way to level the 
warming drawer after it has been installed. If the installation is not 
level, the door may slide open or not seal tightly, allowing heat to 
escape.
NOTE: If installing the warming drawer below another product, 
refer to that product’s literature for any installation requirements.
Product Dimensions
Cabinet Dimensions
Cabinet Side View
WARMING 
DRAWER 
SIZE
OVERALL
WIDTH (A) 
RECESSED
WIDTH (B)
RECESSED
HEIGHT (C)
24"
(61 cm)
23
³⁄₄" 
(60.3 cm)
22
¹⁄₄" 
(56.5 cm)
9"
(22.9 cm)
27" 
(68.6 cm)
26
³⁄₄" 
(67.9 cm)
25
¹⁄₄" 
(64.1 cm)
9"
(22.9 cm)
30" 
(76.2 cm)
29
³⁄₄" 
(75.6 cm)
28
¹⁄₄" 
(71.8 cm)
9"
(22.9 cm)
A
B
C
Warming
drawer
front
Support surface must be
solid, level, flush with
bottom of cabinet cutout.
22
³⁄₄
"
(57.8 cm)
recessed
oven depth
24"
(61 cm)
min. cutout
depth