KitchenAid 30-Inch 5 Burner Gas Double Oven Convection Range Ilustrações Dimensionais

Página de 2
30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
KFGD500E
•  This range is factory set for use with Natural gas. See “Gas
Conversions” section. The model/serial/rating plate is located
on the oven frame behind the top left side of the oven door
has information on the types of gas that can be used. If the types
of gas listed do not include the type of gas available, check
with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial/rating plate for use with a different gas 
without consulting the serving gas supplier. See “Gas Conversions” 
section.
Gas Supply Line
•  Provide a gas supply line if 
3
/
4
" (1.9 cm) rigid pipe to the range
location. A smaller pipe on longer runs may result in insuffient
gas supply. With LP gas, piping or tubing size can be 
1
/
2
"
(1.3 cm) minimum. Usually, LP gas suppliers deteremine the size
and materials used in the system. 
NOTE: Pipe-joint compounds that
resist the action of LP gas must be used. Do not use TEFLON tape.
Flexible metal appliance connector:
•  If local codes permit, a new CSA design-certified, 4 to 5 ft
(122 to 152.4 cm) long, 
1
/
2
" (1.3 cm) or 
3
/
4
" (1.9 cm) I.D.
(inside diameter), flexible metal appliance connector
may be used for connecting range to the gas supply line.
•   A 
1
/
2
" (1.3 cm) male pipe thread is needed for connection
to the female pipe threads of the inlet to the appliance
pressure regulator.
•  Do not kink or damage the flexible metal tubing when moving
the range.
•  Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve.
This valve should be located in the same room but external
to the range opening, such as an adjacent cabinet. It should
be in a location that allows ease of opening and closing. Do not block
access to shutoff valve. The valve is for turning on or shutting off gas
to the range.
A.   35
3
/
4
" ± 
1
/
8
" (90.8 ± 0.3 cm) cooktop height (minimum) 
with leveling legs screwed all the way in**
B.  Model/serial/rating plates (located behind the control panel)*
C.   47
3
/
8
" ± 
1
/
8
" (120.3 ± 0.3 cm) overall height (minimum) 
with leveling legs screwed all the way in**
D.   28
1
/
2
" ± 
1
/
4
" (72.4 ± 0.6 cm) depth with handle
E.   26
1
/
8
" ± 
1
/
8
" (69.2 ± 0.3 cm)***
F.   29
15
/
16
" ± 
1
/
16
" (76.0 ± 0.2 cm) width
*  Model/serial/rating plates may be rotated up from behind the control
panel for viewing front the front of the range.
 **  Range can be raised approximately 1" (2.5 cm) by adjusting 
the leveling legs.
*** Excludes handle. Dimension given is from wall to front of oven door 
and will vary based on electronic outlet receptacle installation.
Because Whirlpool Corporation includes a continues commitment to improve our products, 
we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, 
see Installation Instructions packed with product. Specifications subject 
to change without notice.
GAS SUPPLY REQUIREMENTS
A
B
C
A. Gas supply line
B. Shutoff valve “open” position
C. To range
C**
E***
D
F
A**
B*
ELECTRICAL REQUIREMENTS
To properly install your range, you must determine the type of electrical 
connection you will be using and follow the instructions provided 
for it here.
•  Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located behind the control panel. Refer
to the figure in "Product Dimensions" in the "Location
Requirements" section.
•  This range is manufactured with a 4-wire power supply cord rated
at 240 volts, 40 amps, rated at 194°F (90°C) and investigated for use
with this range.
†®
TEFLON is a registered trademark of E.I. Du Point De Nemours and Company.
Ref. W10694069B
08/10/15
Type of Gas:
Natural Gas:
Range Rating*
Specified Rating of Power 
Supply Cord Kit and Curcuit 
Protection
120/240 Volts
120/208 Volts
Amps
Temp Rating
8.8 – 16.5 KW
7.8 – 12.5 KW
40 or 50
194°F (90°C)
16.6 – 22.5 KW 12.6 – 18.5 KW 50
194°F (90°C)
Page 1 of 2
*  The NEC calculated load is less than the total connected load listed
on the model/serial/rating plate.