Electrical Requirements – Canada Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine 
that the ground path and wire gauge are in accordance with 
local codes.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the CSA Standard C22.1, Canadian 
Electrical Code, Part 1 - latest edition, and all local codes and 
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association 
178 Rexdale Blvd. 
Toronto, ON M9W 1R3 CANADA
 
Check with a qualified electrical installer if you are not sure 
the range is properly grounded.
 
When a 4-wire, single-phase 250-volt, 60 Hz., AC-only 
electrical supply is available, a 40-amp minimum circuit 
protection is required on 30" (76.2 cm) and 36" (91.4 cm) 
ranges and a 50-amp minimum circuit protections is required 
on 48" (121.9 cm) ranges, fused on both sides of the line.
 
A time-delay fuse or circuit breaker is recommended.
 
This range is equipped with a CSA International Certified 
Power Cord intended to be plugged into a standard 14-50R 
wall receptacle. Be sure the wall receptacle is within reach 
of range’s final location.
 
Do not use an extension cord.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1/NFPA 54 - latest edition or CAN/CGA B149 - 
latest edition.
IMPORTANT: Range cooktop must be connected to a regulated 
gas supply.
IMPORTANT: Leak testing of the range cooktop must be 
conducted according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
This range is factory set for use with Natural gas. The model/
serial/rating plate located on the right vertical surface of the oven 
door frame has information on the types of gas that can be used. 
If the types of gas listed do not include the type of gas available, 
check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the range cooktop from 
the gas specified on the model/serial/rating plate for use with 
a different gas without consulting the serving gas supplier. To 
convert to LP gas, use the LP gas conversion kit provided with 
your range and see the “Gas Conversions” section. The parts for 
this kit are in the literature package supplied with the range.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or 
electrical shock.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.