Recording
64
3
Gain
Manual Gain Control
Set the AGC switch to OFF to set the gain manually. You can select one 
of 3 preset gain levels (L: low, M: middle, H: high) to which you can 
independently assign gain values. You can also fine-tune the gain in 
0.5 dB increments.
Assigning Gain Values to the GAIN Switch Positions
You can assign separate gain values to the L, M and H positions of the 
GAIN switch.
1 Open the [Gain] submenu.
[l Camera Setup] 
 [Gain]
2 Select [L], [M] or [H] and then press SET.
3 Select the desired gain level.
• To fine-tune the gain, select [Fine Tuning] and then select the desired 
gain level.
• Repeat steps 2 and 3 to set other switch positions, as necessary.
Available Gain Levels
* These values cannot be selected when the [Gamma] setting in the custom picture 
file is set to [Wide DR].
Applying the Assigned Gain Level
1 Set the AGC switch to OFF.
2 Set the GAIN switch to L, M or H.
• The gain will be set to the level assigned to the selected position of 
the GAIN switch.
[l Camera Setup]
[Gain]
[L   0.0 dB]
[M   6.0 dB]
[H   12.0 dB]
Setting
Description
-6.0 dB*, -3.0 dB*
For the lowest noise recording when recording indoor, low-
light or low-contrast scenes.
0.0 dB*
For lifelike night scenes or scenes under artificial lighting.
3.0 dB*, 6.0 dB, 12.0 dB, 
18.0 dB, 21.0 dB, 33.0 dB
Increases the brightness in indoor or low-light scenes that 
are especially dark.
[Fine Tuning] 
(0.0 dB to 5.5 dB*,
 6 dB to 21.0 dB)
Select [Fine Tuning] to adjust the gain in 0.5 dB increments.
AGC switch
GAIN switch