Maintaining the Controller
144
ProSafe 20-AP Wireless Controller WC7520 
Specify Session Time-Outs
If an HTTP session times out, the user is redirected to the login window for password 
verification.
To specify the length of the HTTP session time-out for the wireless controller:
1. 
Select Maintenance > Remote Management > Session Timeout. The Session 
Timeout screen displays:
Figure 70.  
2. 
In the Timeout (minutes) field, specify number of minutes before an active HTTP login 
session expires.
3. 
Click Apply to save your settings.
View Alerts and Events and Save the Logs
You can view system alerts and save system logs that are collected on the wireless 
controller. You can also save logs of individual access points. In the event of a problem or 
failure, these logs along with backed-up configuration settings could help determine the 
cause.
Save the Logs
To save access point logs:
1. 
Select Maintenance > Logs & Alerts > Save Logs > AP Logs. The Access Points 
screen displays: