Netgear M7100-24X (XSM7224) - ProSAFE 24 Ports 10G Fully Managed L2 Switch Guia Do Programa
Configure System Information
117
M6100, M5300, and M7100 Series Managed Switches
This sets the threshold level at which a trap is sent if consumed power is greater than the
threshold power.
threshold power.
10.
The Power Management mode describes or controls the power management algorithm
used by the PSE to deliver power to the requesting PDs.
Select Static to indicate that the power allocated for each port depends on the type of
power threshold configured on the port. Select Dynamic to indicate that the power
consumption on each port is measured and calculated in real-time.
power threshold configured on the port. Select Dynamic to indicate that the power
consumption on each port is measured and calculated in real-time.
11.
To set the traps, select Enable to activate the PoE traps.
Select Disable to deactivate the PoE traps. The default setting is enabled.
12.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
immediately.
The following table describes the PoE Configuration nonconfigurable fields.
Configure PoE Ports
To configure PoE port settings:,
1.
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
2.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
3.
Launch a web browser.
Table 41. PoE Configuration
Field
Description
Units
The current PoE Unit. You can change the PoE Unit by selecting
another unit ID listed here.
another unit ID listed here.
Firmware Version
The version of the PoE controller's FW image.
Power Status
Indicates the power status.
Total Power (Main AC)
The total power provided by the MAIN AC power source.
Total Power (RPS)
Total Power (PD) for GSM5212P
switches only
Total Power (PD) for GSM5212P
switches only
The total power provided by the redundant power source.
Power Source
Current source of system power (Main AC or RPS).
Threshold Power
System can power up one port, if consumed power is less than this
power. i.e. Consumed power can be between Nominal and Threshold
Power values. The threshold power value is effected by changing
System Usage Threshold.
power. i.e. Consumed power can be between Nominal and Threshold
Power values. The threshold power value is effected by changing
System Usage Threshold.
Consumed Power
Total amount of a power which is currently being delivered to all ports.