Netgear M7100-24X (XSM7224) - ProSAFE 24 Ports 10G Fully Managed L2 Switch Guia Do Programa
Manage Device Security
628
M6100, M5300, and M7100 Series Managed Switches
Configure the DAI Interface
To configure the DAI interface:
1.
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
2.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
3.
Launch a web browser.
4.
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
5.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
6.
Click the Login button.
The web management interface menu displays.
7.
Select Security > Control > Dynamic ARP Inspection > DAI Interface Configuration.
8.
Use the Interface check boxes to select the physical interface.
9.
Use Trust Mode to indicate whether the interface is trusted for dynamic ARP inspection
purposes.
If this is set to Enable, the interface is trusted. ARP packets coming to this interface are
forwarded without checking. If this is set to Disable, the interface is not trusted. ARP
packets coming to this interface are subjected to ARP inspection. The factory default is
Disable.
forwarded without checking. If this is set to Disable, the interface is not trusted. ARP
packets coming to this interface are subjected to ARP inspection. The factory default is
Disable.
10.
Use Rate Limit (pps) to specify rate limit value for dynamic ARP inspection purpose.
If the incoming rate of ARP packets exceeds the value of this for consecutive burst
interval seconds, ARP packets are dropped. If this value is N/A, there is no limit. The
interval seconds, ARP packets are dropped. If this value is N/A, there is no limit. The