Netgear M7100-24X (XSM7224) - ProSAFE 24 Ports 10G Fully Managed L2 Switch Guia Do Programa
Maintenance
729
M6100, M5300, and M7100 Series Managed Switches
Copy an Image
To copy an image:
1.
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
2.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
3.
Launch a web browser.
4.
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
5.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
6.
Click the Login button.
The web management interface menu displays.
7.
Select Maintenance > File Management > Copy.
8.
Use Source Image to select the image1 or image2 as the source image (the image to be
copied).
9.
Use Chassis Member to select the destination unit to which you are going to copy from the
supervisor.
10.
Use Destination Image to select the image1 or image2 as the destination image.
11.
Click the Apply button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
immediately.
Configure Dual Image Settings
The Dual Image feature allows the switch to retain two images in permanent storage. The
administrator can designate image1 or image2 as the active image to be loaded during
subsequent switch restarts. This feature reduces switch down time when you are upgrading
or downgrading the software image.
administrator can designate image1 or image2 as the active image to be loaded during
subsequent switch restarts. This feature reduces switch down time when you are upgrading
or downgrading the software image.