Netgear M7100-24X (XSM7224) - ProSAFE 24 Ports 10G Fully Managed L2 Switch Guia Do Programa
Configure System Information
82
M6100, M5300, and M7100 Series Managed Switches
Configure the Green Ethernet EEE LPI History
To configure the port Green Mode EEE history:
1.
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
2.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
3.
Launch a web browser.
4.
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
5.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
6.
Click the Login button.
Cumulative Energy Saving per
Chassis (Watts * Hours)
Chassis (Watts * Hours)
Estimated cumulative energy saved per chassis in (watts * hour) when
all green modes are enabled.
all green modes are enabled.
Unit
The Unit ID.
Green Features supported on this
unit
unit
List of green features supported on the given unit, which could be one
or more of the following: Energy-Detect (Energy Detect), Short-Reach
(Short Reach), EEE (Energy Efficient Ethernet), LPI-History (EEE Low
Power Idle History), LLDP-Cap-Exchg (EEE LLDP Capability
Exchange), Pwr-Usg-Est (Power Usage Estimates).
or more of the following: Energy-Detect (Energy Detect), Short-Reach
(Short Reach), EEE (Energy Efficient Ethernet), LPI-History (EEE Low
Power Idle History), LLDP-Cap-Exchg (EEE LLDP Capability
Exchange), Pwr-Usg-Est (Power Usage Estimates).
Interface
Interface for which data is displayed or configured.
Energy Detect Admin mode
Enable or disable Energy Detect mode on the port. When this mode is
enabled, when the port link is down, the PHY automatically goes down
for a short period of time, then wakes up to check link pulses. This
allows the switch to perform autonegotiation and save power
consumption when no link partner is present.
enabled, when the port link is down, the PHY automatically goes down
for a short period of time, then wakes up to check link pulses. This
allows the switch to perform autonegotiation and save power
consumption when no link partner is present.
Energy Detect Operational Status Current operational status of the Energy Detect mode.
Short Reach Admin mode
Enable or disable Short Reach Admin mode on the port. With Short
Reach mode enabled, PHY is forced to operate in low power mode
irrespective of the cable length.
Reach mode enabled, PHY is forced to operate in low power mode
irrespective of the cable length.
Short Reach Operational Status
Current operational status of the Short Reach mode.
EEE Admin mode
Enable or disable Energy Efficient Ethernet mode on the port. With
EEE mode enabled, the port transitions to low power mode during link
idle conditions.
EEE mode enabled, the port transitions to low power mode during link
idle conditions.
Table 29. Green Ethernet Statistics Summary (continued)
Field
Description