Netgear M7100-24X (XSM7224) - ProSAFE 24 Ports 10G Fully Managed L2 Switch Guia Do Administrador

Página de 721
iSCSI 
712
Managed Switches 
Show iSCSI Sessions
The example is shown as CLI commands and as web interface procedure
CLI: Show iSCSI Sessions
Use the following commands to show iSCSI sessions and session details:
(Netgear Switch)  #show iscsi sessions
Session 0:
--------------------------------------------------------------------------
Target: iqn.2012-08.com.example:storage.lun1
Initiator: iqn.1991-05.com.microsoft:netgear-think
ISID: 400001370000
(Netgear Switch)  #show iscsi sessions detailed
Session 0:
--------------------------------------------------------------------------
Target: iqn.2012-08.com.example:storage.lun1
Initiator: iqn.1991-05.com.microsoft:netgear-think
Up Time: 00:00:04:11 (DD:HH:MM:SS)
Time for aging out: 382 secs
ISID: 400001370000
Initiator 
 
             Initiator      
 
Target 
 
                 Target
IP Address
 
             TCP Port
 
         IP Address     
 
    
    TCP Port
-------------------
 
  -------------   -------------------- 
 
 -------------
192.168.10.107   
 
     57965         
 
 192.168.10.116   
 
      3260
(Netgear Switch) #
The command shows that there is an active iSCSI session. The initiator is at IP address 
192.168.10.107 and the Target is at IP address 192.168.10.116