Netgear M7100-24X (XSM7224) - ProSAFE 24 Ports 10G Fully Managed L2 Switch Guia Do Administrador
iSCSI
712
Managed Switches
Show iSCSI Sessions
The example is shown as CLI commands and as web interface procedure
CLI: Show iSCSI Sessions
Use the following commands to show iSCSI sessions and session details:
(Netgear Switch) #show iscsi sessions
Session 0:
--------------------------------------------------------------------------
Target: iqn.2012-08.com.example:storage.lun1
Initiator: iqn.1991-05.com.microsoft:netgear-think
ISID: 400001370000
(Netgear Switch) #show iscsi sessions detailed
Session 0:
--------------------------------------------------------------------------
Target: iqn.2012-08.com.example:storage.lun1
Initiator: iqn.1991-05.com.microsoft:netgear-think
Up Time: 00:00:04:11 (DD:HH:MM:SS)
Time for aging out: 382 secs
ISID: 400001370000
Initiator
Initiator
Target
Target
IP Address
TCP Port
IP Address
TCP Port
-------------------
------------- --------------------
-------------
192.168.10.107
57965
192.168.10.116
3260
(Netgear Switch) #
The command shows that there is an active iSCSI session. The initiator is at IP address
192.168.10.107 and the Target is at IP address 192.168.10.116