Utilities
Table 22.  Trap Mgr Log Message
Component
Message
Cause
Trap Mgr
Link Up/Down: unit/slot/port
An interface changed link state.
Table 23.  DHCP Filtering Log Messages
Component
Message
Cause
DHCP Filtering
Unable to create r/w lock for DHCP Filtering
Unable to create semaphore used for dhcp 
filtering configuration structure.
DHCP Filtering
Failed to register with nv Store.
Unable to register save and restore functions for 
configuration save.
DHCP Filtering
Failed to register with NIM
Unable to register with NIM for interface callback 
functions.
DHCP Filtering
Error on call to sysapiCfgFileWrite file
Error on trying to save configuration.
Table 24.  NVStore Log Messages
Component
Message
Cause
NVStore
Building defaults for file XXX
A component’s configuration file does not exist or 
the file’s checksum is incorrect so the 
component’s default configuration file is built.
NVStore
Error on call to osapiFsWrite routine on file XXX
Either the file cannot be opened or the OS’s file 
I/O returned an error trying to write to the file.
NVStore
File XXX corrupted from file system. Checksum 
mismatch.
The calculated checksum of a component’s 
configuration file in the file system did not match 
the checksum of the file in memory.
NVStore
Migrating config file XXX from version Y to Z
A configuration file version mismatch was 
detected so a configuration file migration has 
started.
Table 25.  RADIUS Log Messages 
Component
Message
Cause
RADIUS
RADIUS: Invalid data length - xxx
The RADIUS Client received an invalid message 
from the server.
RADIUS
RADIUS: Failed to send the request
A problem communicating with the RADIUS 
server.