Netgear M4300-24X24F (XSM4348S) - Stackable Managed Switch with 48x10G including 24x10GBASE-T and 24xSFP+ Layer 3 Guia Do Programa

Página de 1143
Utility Commands 
335
 M4200 and M4300 Series ProSAFE Managed Switches
Remote Monitoring Commands
Remote Monitoring (RMON) is a method of collecting a variety of data about network traffic. 
RMON supports 64-bit counters (RFC 3273) and High Capacity Alarm Table (RFC 3434). 
Note:
There is no configuration command for ether stats and high capacity 
ether stats. The data source for ether stats and high capacity ether 
stats are configured during initialization.rmon alarm
rmon alarm
This command sets the RMON alarm entry in the RMON alarm MIB group.
Format
rmon alarm alarm-number variable sample-interval {absolute | delta} 
rising-threshold value [rising-event-index] falling-threshold value 
[falling-event-index] [startup {rising | falling | rising-falling}] [owner 
string]
Mode
Global Config
Parameter
Description
Alarm Index
An index that uniquely identifies an entry in the alarm table. Each entry defines a diagnostic sample 
at a particular interval for an object on the device. The range is 1 to 65535.
Alarm Variable
The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 
primitive type of integer.
Alarm Interval
The interval in seconds over which the data is sampled and compared with the rising and falling 
thresholds. The range is 1 to 2147483647. The default is 1.
Alarm Absolute 
Value
The value of the statistic during the last sampling period. This object is a read-only, 32-bit signed 
value.
Alarm Rising 
Threshold
The rising threshold for the sample statistics. The range is 2147483648 to 2147483647. The default 
is 1.
Alarm Rising Event 
Index
The index of the eventEntry that is used when a rising threshold is crossed. The range is 1 to 65535. 
The default is 1.
Alarm Falling 
Threshold
The falling threshold for the sample statistics. The range is 2147483648 to 2147483647. The default 
is 1.
Alarm Falling Event 
Index
The index of the eventEntry that is used when a falling threshold is crossed. The range is 1 to 65535. 
The default is 2.
Alarm Startup 
Alarm
The alarm that may be sent. Possible values are rising, falling or both rising-falling. The default is 
rising-falling.
Alarm Owner
The owner string associated with the alarm entry. The default is monitorAlarm.